Airway mechanosensor behavior during application of positive end-expiratory pressure.

نویسندگان

  • Juan Guardiola
  • Bryan Moffett
  • Huafeng Li
  • Rajeesh Punnakkattu
  • Bogden Moldoveanu
  • Jun Liu
  • Lei Du
  • Jerry Yu
چکیده

BACKGROUND Positive end-expiratory pressure (PEEP) is commonly used in clinical settings. It is expected to affect the input from slowly adapting pulmonary stretch receptors (SARs), leading to altered cardiopulmonary functions. However, we know little about how SARs behave during PEEP application. OBJECTIVES Our study aimed to characterize the behavior of SARs during PEEP application. METHODS We recorded single-unit activities from 18 SARs in the cervical vagus nerve and examined their response to an increase of PEEP from 3 to 10 cm H2O for 20 min in anesthetized, open-chest and mechanically ventilated rabbits. RESULTS The mean activity of the units increased immediately from 35.7 to 80.5 impulses per second at the fifth breath after increasing PEEP (n = 14, p < 0.001) and then gradually returned to 56.5 impulses per second at the end of 20 min of PEEP application (p < 0.001). In the meantime, peak airway pressure increased from 9.3 to 32.7 cm H2O, and then gradually returned to 29.4 cm H2O (n = 18; p < 0.05) after 20 min. The remaining four units ceased firing at 34.7 s (range 10-56 s) after their initial increased activity upon 10 cm H2O PEEP application. The unit activity resumed as the PEEP was returned to 3 cm H2O. CONCLUSIONS High PEEP stimulates SARs and SAR activity gradually returns towards the baseline via multiple mechanisms including receptor deactivation, neural habituation and mechanical adaptation. Understanding of the sensory inputs during PEEP application will assist in developing better strategies of mechanical ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of continuous positive airway pressure to the non-ventilated lung during one-lung ventilation with low tidal volumes

INTRODUCTION In multiple study populations large tidal volumes (8 - 12 ml/kg) have deleterious effects on lung function in multiple study populations. The accepted approach to hypoxemia during one-lung ventilation is the application of continuous positive airway pressure to the non-ventilated lung first, followed by application of positive end-expiratory pressure to the ventilated lung. To our ...

متن کامل

Intrinsic PEEP and cardiopulmonary interaction in patients with COPD and acute ventilatory failure.

Deviation of end-expiratory lung volume from the elastic equilibrium volume of the respiratory system is recognized as a cardinal feature in mechanically-ventilated patients with severe chronic obstructive pulmonary disease (COPD) and acute ventilatory failure (AVF). The presence of dynamic hyperinflation implies that alveolar pressure remains positive throughout expiration. At the end of the e...

متن کامل

Analysis of Respiratory Behavior and Clinical Parameters for Successful Extubation in Premature Infants

Background The weaning process is complex and needs to be done carefully. The success of extubation in premature babies is associated with brain maturity and adequate function of the lungs. We aimed to identify the ventilator parameters and clinical conditions related to extubation success and failure in premature infants. Materials and Methods This is anobservational study, analytical and non-...

متن کامل

Positive Expiratory Pressure (PEP) versus Conventional Chest Physiotherapy in Pediatric Patients with Acute Exacerbation of Cystic Fibrosis

Background Pulmonary involvement is the main cause of mortality in cystic fibrosis (CF). Airway clearance techniques are non-pharmacological complement options for CF patients. The aim of this study was to evaluate the short-term outcome of airway cleaning treatment in patients with cystic fibrosis in a children's hospital. Materials and Methods This clinical trial study conducted on 40 CF pati...

متن کامل

Physiological responses to positive expiratory pressure breathing: a comparison of the PEP bottle and the PEP mask.

BACKGROUND In the intensive care unit we have observed that patients have different adherence to 2 commonly used positive-expiratory-pressure (PEP) therapy devices: the PEP bottle and the PEP mask. The reason for this difference is not clear. METHODS In a randomized prospective study, we made continuous recordings of airway pressure and airflow, with 20 healthy volunteers, with the PEP bottle...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiration; international review of thoracic diseases

دوره 88 4  شماره 

صفحات  -

تاریخ انتشار 2014