Screening for pre-eclampsia in the first trimester: role of maternal hemodynamics and bioimpedance in non-obese patients.
نویسندگان
چکیده
OBJECTIVE To test if maternal hemodynamics and bioimpedance, assessed at the time of combined screening for PE, are able to identify in the first trimester of gestation normotensive non-obese patients at risk for pre-eclampsia (PE) and/or intrauterine growth restriction (IUGR). METHODS One hundred and fifty healthy nulliparous non-obese women (body mass index < 30 kg/m2 ) in the first trimester of pregnancy underwent assessment by UltraSonic Cardiac Output Monitor (USCOM) to detect hemodynamic parameters, bioimpedance analysis to characterize body composition, and combined screening for PE (assessment of maternal history, biophysical and maternal biochemical markers). Patients were followed until term, noting the appearance of PE and/or IUGR. RESULTS One hundred and thirty-eight patients had an uneventful pregnancy (controls), while 12 (8%) developed complications (cases). USCOM showed, in cases compared with controls, lower cardiac output (5.6 ± 0.3 vs 6.7 ± 1.1 L/min, P < 0.001), lower inotropy index (1.54 ± 0.38 vs 1.91 ± 0.32 W/m2 , P < 0.001) and higher total vascular resistance (1279.8 ± 166.4 vs 1061.4 ± 179.5 dynes × s/cm5 , P < 0.001). Bioimpedance analysis showed, in cases compared with controls, lower total body water (53.7 ± 3.3% vs 57.2 ± 5.6%, P = 0.037). Combined screening was positive for PE in 8% of the controls and in 50% of the cases (P < 0.001). After identification of cut-off values for USCOM and bioimpedance parameters, forward multivariate logistic regression analysis identified as independent predictors of complications in pregnancy the inotropy index (derived by USCOM), fat mass (derived from bioimpedance analysis) and combined screening. CONCLUSIONS Combined screening for PE and assessment of bioimpedance and maternal hemodynamics can be used to identify early markers of impaired cardiovascular adaptation and body composition that may lead to complications in the third trimester of pregnancy. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
منابع مشابه
Soluble CD30 in Normal Pregnancy Pre-Eclampsia and Recurrent Pregnancy Loss
Background: Normal pregnancy is thought to be dependent on Th2 deviation, while Recurrent Pregnancy Loss (RPL) and Pre-eclampsia (PE) appear to be biased toward the Th1 immune response. It is believed that the soluble form of CD30 (sCD30) is an index of Th2 immune response or modulator of Th1/Th2 responses. Objective: The aim of this study was determination of the sCD30 level in RPL and PE pati...
متن کاملP-90: Maternal Susceptibility to Pre-Eclampsia in South Indian Women: FOXP3 Gene
Background: Pre-eclampsia is a multifactorial pregnancy specific vascular disorder characterized by hypertension and proteinuria. It affects around 3-5% pregnancies worldwide. The aetiology and pathophysiology of PE remain poorly understood. But it is generally accepted defective placentation during the early stage of pregnancy most likely in combination with maternal and environmental factors ...
متن کاملEvaluation of Serum Calcium, Magnesium, Copper, and Zinc Levels in Women with Pre-eclampsia
Background: Pre-eclampsia along with its complications seems to be one of the major causes of maternal morbidity and mortality. Despite numerous studies, the etiology of pre-eclampsia has not yet been fully elucidated. According to recent studies changes in the level of blood trace elements can be an adverse event in human and animal pregnancy. The present study determines whether maternal seru...
متن کاملThe Role of Increased Uric Acid in Predicting Pre-eclampsia at The Gestational Age of 24-28 Weeks
Abstract Background and objectives: Despite prenatal care, pre-eclampsia is still one of the most important causes of maternal and fetal mortality. There is no screening test for pre-eclampsia to be reliable and economical. One of the most accessible and easiest screening tests is blood uric acid measurement. The goal of this study is to assess the level of uric acid in high risk pregnant women...
متن کاملCorrelation of pregnancy outcome with quadruple screening test at second trimester
Background: Abnormal levels of the markers AFP, hCG, and uE3 could be useful in predicting adverse pregnancy outcomes. This study was designed to determine the correlation between second trimester maternal serum markers and adverse pregnancy outcome (APO). Methods: In this historical cohort study, we randomly followed 231 obstetric patients with quadruple screening test in 14-18 weeks of ges...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology
دوره 50 5 شماره
صفحات -
تاریخ انتشار 2017