Response of thermocouples interfaced to electrothermometers when immersed in 5 water bath temperatures.

نویسندگان

  • Blaine C Long
  • Lisa S Jutte
  • Kenneth L Knight
چکیده

CONTEXT Thermocouples and electrothermometers are used in therapeutic modality research. Until recently, researchers assumed that these instruments were valid and reliable. OBJECTIVE To examine 3 different thermocouple types in 5 degrees C, 15 degrees C, 18.4 degrees C, 25 degrees C, and 35 degrees C water baths. DESIGN Randomized controlled trial. SETTING Therapeutic modality laboratory. INTERVENTION(S) Eighteen thermocouple leads were inserted through the wall of a foamed polystyrene cooler. The cooler was filled with water. Six thermocouples (2 of each model) were plugged into the 6 channels of the Datalogger and 6 randomly selected channels in the 2 Iso-Thermexes. A mercury thermometer was immersed into the water and was read every 10 seconds for 4 minutes during each of 6 trials. The entire process was repeated for each of 5 water bath temperatures (5 degrees C, 15 degrees C, 18.4 degrees C, 25 degrees C, 35 degrees C). MAIN OUTCOME MEASURE(S) Temperature and absolute temperature differences among 3 thermocouple types (IT-21, IT-18, PT-6) and 3 electrothermometers (Datalogger, Iso-Thermex calibrated from -50 degrees C to 50 degrees C, Iso-Thermex calibrated from -20 degrees C to 80 degrees C). RESULTS Validity and reliability were dependent on thermocouple type, electrothermometer, and water bath temperature (P < .001; modified Levene P < .05). Statistically, the IT-18 and PT-6 thermocouples were not reliable in each electrothermometer; however, these differences were not practically different from each other. The PT-6 thermocouples were more valid than the IT-18s, and both thermocouple types were more valid than the IT-21s, regardless of water bath temperature (P < .001). CONCLUSIONS The validity and reliability of thermocouples interfaced to an electrothermometer under experimental conditions should be tested before data collection. We also recommend that investigators report the validity, the reliability, and the calculated uncertainty (validity + reliability) of their temperature measurements for therapeutic modalities research. With this information, investigators and clinicians will be better able to interpret and compare results and conclusions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability and validity of electrothermometers and associated thermocouples.

OBJECTIVE Examine thermocouple model uncertainty (reliability+validity). DESIGN First, a 3x3 repeated measures design with independent variables electrothermometers and thermocouple model. Second, a 1x3 repeated measures design with independent variable subprobe. INTERVENTION Three electrothermometers, 3 thermocouple models, a multi-sensor probe and a mercury thermometer measured a stable w...

متن کامل

Spinal cord transection inhibits HR reduction in anesthetized rats immersed in an artificial CO2-hot spring bath.

Like humans, the heart rate (HR) of anesthetized rats immersed in CO(2)-water is lower than that when immersed in tap water at the same temperature. To investigate the afferent signal pathway in the mechanism of HR reduction, Wistar rats were anesthetized with urethane and then the spinal cord was transected between T(4) and T(5). The animals were immersed up to the axilla in a bathtub of tap-w...

متن کامل

Decrease in heart rates by artificial CO2 hot spring bathing is inhibited by beta1-adrenoceptor blockade in anesthetized rats.

To investigate the effects of carbon dioxide (CO2) hot spring baths on physiological functions, head-out immersion of urethane-anesthetized, fursheared male Wistar rats was performed. Animals were immersed in water (30 or 35 degrees C) with high-CO2 content ( approximately 1,000 parts/million; CO2-water). CO2-water for bathing was made by using an artificial spa maker with normal tap water and ...

متن کامل

Study of Photo-Conductivity in MoS2 Thin Films Grown in Low-Temperature Aqueous Solution Bath

An experimental study over the optical response of thin MoS2 films grownby chemical bath deposition (CBD) method is presented. As two important factors, theeffect of bath temperature and growth time are considered on the photocurrentgeneration in the grown samples. The results show that increasing the growth time leadsto better optical response and higher difference betw...

متن کامل

Experimental study: Investigation of graphene oxide nanoparticles effect on increasing the thermal effect of ultrasound waves on water for thermal therapy of cancer cells

Background & Aim: Ultrasound hyperthermia with nanoparticles has been regarded as an effective method for localized death of cancerous cells with fewer side effects to the surrounding normal tissues. The aim of this study was to investigate the increasing of water temperature by ultrasound waves in the presence of graphene oxide (GO) nanoparticles in order to be used in thermal treatment of can...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of athletic training

دوره 45 4  شماره 

صفحات  -

تاریخ انتشار 2010