Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation.
نویسندگان
چکیده
BACKGROUND Ablation of complex arrhythmias would be greatly facilitated by more precise control of ablation catheters. A feasibility study was performed in animals to evaluate a novel magnetic guidance system (MGS) that generates a magnetic field to control the movement and position of a magnetic ablation catheter. METHODS AND RESULTS The MGS is composed of a digital biplanar fluoroscope within an array of superconducting electromagnets that surround the torso of the experimental animal and a computer control system that generates a composite magnetic field for directional catheter deflection. Magnetic catheter navigation was performed in dogs and pigs (20 to 30 kg). A 7F magnetic ablation catheter was used for intracardiac navigation and radiofrequency ablation. The performance of a standard 7F deflectable catheter was not affected by the MGS. The magnetic catheter was navigated successfully to 51 predefined targets throughout the heart in 6 animals. In 5 animals, the magnetic catheter, guided by a 3D computed tomogram, was successfully navigated to all pulmonary veins. Navigation accuracy was estimated as <1 mm displacement from the target. The magnetic catheter was used to ablate the atrioventricular node in 4 animals and to perform linear ablations across the endocardial surface underlying an epicardial multielectrode recording plaque in 4 animals. CONCLUSIONS These results demonstrate that the MGS can navigate and stabilize an ablation catheter at endocardial targets. Linear or focal radiofrequency ablation with the magnetic catheter is not compromised by the magnetic field. This technology provides precise control of endocardial catheters.
منابع مشابه
Mapping and ablation of ventricular tachycardia guided by virtual electrograms using a noncontact, computerized mapping system.
OBJECTIVES The purpose of this study was to describe a computerized mapping system that utilizes a noncontact, 64 electrode balloon catheter to compute virtual electrograms simultaneously at 3,360 left ventricular (LV) sites and to assess the clinical utility of this system for mapping and ablating ventricular tachycardia (VT). BACKGROUND Mapping VT in the electrophysiology laboratory convent...
متن کاملRadiofrequency catheter ablation guided by intracardiac echocardiography.
BACKGROUND Radiofrequency catheter ablation requires precise positioning of the ablation electrode. Fluoroscopically guided catheter manipulation has limitations, and there are risks of radiation exposure. The purpose of this study was to examine the feasibility of guiding catheter ablation within the right atrium with catheter-based intracardiac echocardiography. METHODS AND RESULTS A 10F, 1...
متن کاملFeasibility of Rapid Linear-Endocardial and Epicardial Ventricular Ablation Using an Irrigated Multipolar Radiofrequency Ablation Catheter.
BACKGROUND A common strategy for ablation of scar-based ventricular tachycardia is delivering multiple lesions in a linear pattern. METHODS AND RESULTS We tested the efficacy of a novel linear irrigated multipolar ablation catheter capable of creating linear lesions with a single application. Healthy swine underwent endocardial and epicardial linear ablation using a novel linear irrigated abl...
متن کاملAngiographic and electrophysiological substrates for ventricular tachycardia mapping through the coronary veins.
OBJECTIVE To study the value of epicardial mapping through the coronary venous system in patients with sustained ventricular tachycardia. DESIGN 20 consecutive patients with sustained ventricular tachycardia who were candidates for radiofrequency ablation. SETTING Electrophysiological laboratory. INTERVENTIONS Coronary venous angiography was performed with a catheter, which provided coron...
متن کاملEndocardial activation mapping of ventricular tachycardia in patients : first application of a 32-site bipolar mapping electrode catheter.
BACKGROUND Localization of early activated endocardial areas during ventricular tachycardia (VT) is mandatory for performance of surgical or radiofrequency catheter interventions. The use of a multielectrode catheter may shorten the procedure time and increase the accuracy of the procedure compared with single-electrode mapping techniques. This study was performed to evaluate the safety and eff...