Quantitative assessment of cerebral blood volume by single-photon emission computed tomography.

نویسندگان

  • U Sabatini
  • P Celsis
  • G Viallard
  • A Rascol
  • J P Marc-Vergnes
چکیده

We implemented a technique for measuring regional cerebral blood volume using single-photon emission computed tomography and in vivo technetium-99m-labeled red blood cells and then evaluated it in nine normal human volunteers (controls) and seven patients with bilateral occlusion or severe stenosis of the internal carotid artery. We also measured regional cerebral blood flow using single-photon emission computed tomography and intravenous xenon-133 in the same subjects. We studied regional cerebral blood flow, regional cerebral blood volume, and their ratio before and after the intravenous injection of 1 g acetazolamide. Mean +/- SD baseline regional cerebral blood volume was higher in the patients than in the controls (4.1 +/- 0.6 versus 3.2 +/- 0.3 ml/100 g, p less than 0.01), and mean +/- SD baseline regional cerebral blood flow was lower in the patients than in the controls (40.5 +/- 11 versus 55.6 +/- 11 ml/100 g/min, p less than 0.05). Acetazolamide induced similar mean +/- SD increases in regional cerebral blood volume in both the controls and the patients (0.3 +/- 0.1 and 0.3 +/- 0.2 ml/100 g), while the mean +/- SD regional cerebral blood flow reactivity was significantly less in the patients than in the controls (12.6 +/- 7.6 versus 24.5 +/- 9.6 ml/100 g/min, p less than 0.05). Our study shows that single-photon emission computed tomography can provide quantitative estimates of both regional cerebral blood volume and regional cerebral blood flow in humans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Abnormal cerebral blood flow in methamphetamine abusers assessed by brain perfusion single emission computed tomography

Introduction:Amphetamines are central nervous system (CNS) stimulant substances and amphetamine abuse is considered a growing problem in our country. Previous studies revealed destructive effects of amphetamines on metabolism, perfusion and structure of brain. The aim of current study was evaluating regional cerebral blood flow (rCBF) disturbances in methamphetamine (MA) abuser...

متن کامل

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

Sequential assessment of regional cerebral blood flow, regional cerebral blood volume, and blood-brain barrier in focal cerebral ischemia: a case report.

Regional CBF (rCBF) and regional cerebral blood volume (rCBV) were evaluated by N,N,N'-trimethyl-N'-(2)-hydroxy-3-methyl-5-[123I]iodobenzyl-1, 3-propanediamine-2 HCl- and 99mTC-labeled red blood cells, respectively, and single-photon emission computerized tomography (SPECT) in a patient with focal cerebral ischemia. Sequential transmission computerized tomography (TCT) and SPECT functional data...

متن کامل

Comparison of Perfusion Weighted Magnetic Resonance Imaging and Single Photon Emission Computed Tomography for Assessment of Cerebrovascular Reserve in Symptomatic Carotid Territory Stenosis

Background: Perfusion Weighted Magnetic Resonance Imaging (PW-MRI) and HMPAO Single Photon Emission Computed Tomography (SPECT) are both cerebral perfusion measurement techniques. Imaging before and after acetazolamide administration can assess cerebrovascular reserve in symptomatic haemodynamic cerebrovascular disease. We compared SPECT and PW-MRI parameters in this patient group. Methods: We ...

متن کامل

Improvement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database

Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the util...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 22 3  شماره 

صفحات  -

تاریخ انتشار 1991