Experimental Technique for Measuring the Long - term Transfer Length in
نویسنده
چکیده
This paper presents a proposal of a test setup and methodology for testing the transfer length evolution through time of prestressing reinforcement in pretensioned prestressed concrete members, aimed at providing a basis for standardization. The proposed test method is based on the instantaneous and time-related analysis of the prestressing reinforcement force profile at only one end of a pretensioned prestressed concrete member. The basis of the test method and the requirements of the prestressing frame and its components are presented, as well as the test procedure stages and the measurement devices. The interpretation of the test results and the criteria to determine both the initial and the long-term transfer lengths are explained. A test method application and the equipment for testing seven-wire prestressing strands have been designed. Some experimental results are provided to validate the test. A comparative analysis of test reliability with other existing experimental methods is also included.
منابع مشابه
Priming Effect of on the Enhancement of Germination Traits in Aged Seeds of Chamomile (Matricaria chamomilla L.) Seeds Preserved in Medium and Long-term Storage
Chamomile (Matricaria chamomilla L.) is a widely used medicinal plant possessing several pharmacological effects due to presence of active compounds. In order to study of seed priming effects on seedling growth of chamomile, an experimental design, based on randomized complete design with three replications was conducted under greenhouse conditions in Research Institute of Forests and Rangeland...
متن کاملHeat Transfer from a Tube Bank in Cross Flow in a Duct
An experimental investigation on heat transfer coefficient is presented from three horizontal tubes in a vertical array in a duct for 500<ReD<6000. A mass transfer measuring technique based on psychrometry chart is used to determine heat transfer coefficient. The diameter of the tubes is 11 mm each spaced 40 mm apart and in-line pitch ratio varies in the range 0.055<D/W<0.22. The experimenta...
متن کاملHeat Transfer from a Tube Bank in Cross Flow in a Duct
An experimental investigation on heat transfer coefficient is presented from three horizontal tubes in a vertical array in a duct for 500<ReD<6000. A mass transfer measuring technique based on psychrometry chart is used to determine heat transfer coefficient. The diameter of the tubes is 11 mm each spaced 40 mm apart and in-line pitch ratio varies 
in the range 0.055<D/W<0.22. The experimen...
متن کاملEffect of long-term intake of Vitasil on ultrasound and blood biochemical parameters associated with fatty liver disease in common carp (Cyprinus carpio)
Fatty liver disease (FLD) is the most common cause of chronic liver disease in fish in the whole world. In the present study, the hepatoprotective effect of preparatıon Vitasil content extract of Milk thistle (Silybum marianum) was evaluated by ultrasound examination of liver and measuring biochemical parameters of liver function. 240 carp were randomly assigned into three groups (two experimen...
متن کاملEffect of Seed Priming on Enhancement of Seed Germination and Seedling Growth of Annual Sainfoin (Onobrychis crista-galli (L.) Lam.) in Medium and Long-term Collections of Gene Bank
Annual Sainfoin (Onobrychis crista-galli (L.) Lam.) is widely adapted to moderate and cold regions of Iran and naturally grows in pasture and rangelands used for forage in these areas. In order to study the effects of priming on seed germination and seedling growth in O. crista-galli, two factorial experiments were conducted based on a randomized complete design with three replications under la...
متن کامل