Identification of predictive CT angiographic factors in the development of high-risk type 2 endoleaks after endovascular aneurysm repair in patients with infrarenal aortic aneurysms.

نویسندگان

  • D Löwenthal
  • L Herzog
  • B Rogits
  • K Bulla
  • S Weston
  • F Meyer
  • Z Halloul
  • M Pech
  • J Ricke
  • O Dudeck
چکیده

PURPOSE An extensive analysis of the value of computed tomography (CT) parameters as potential predictors of the clinical outcome of type 2 endoleaks after endovascular aortic aneurysm repair (EVAR). MATERIALS AND METHODS Initial CT scans of 130 patients with abdominal aortic aneurysms (AAAs) were retrospectively reviewed. On the basis of postoperative CT scans and angiographies, patients were stratified into a low-risk group (LRG; without or transient type 2 endoleak; n = 80) and a high-risk group (HRG, persistent type 2 endoleak or need for reintervention; n = 50). Statistical analysis comprised a univariate and multivariate analysis. RESULTS Anatomical, thrombus-specific, as well as aortic side branch parameters were assessed on the initial CT scan. Of all anatomical parameters, the diameter of the immediate infrarenal aorta was significantly different in the univariate analysis (LRG 22.4 ± 3.8 mm; HRG 23.6 ± 2.5 mm; p = 0.03). The investigation of the thrombus-specific parameters showed a trend towards statistical significance for the relative thrombus load (LRG 31.7 ± 18.0%; HRG 25.3 ± 17.5%; p = 0.09). Assessment of aortic side branches revealed only for the univariate analysis significant differences in the patency of the inferior mesenteric artery (LRG 71.3%; HRG 92.0%; p = 0.003) and their diameter (LRG 3.3 ± 0.7 mm; HRG 3.8 ± 0.9 mm; p = 0.004). In contrast, the number of lumbar arteries (LAs; LRG 2.7 ± 1.4; HRG 3.6 ± 1.2; univariate: p = 0.01; multivariate: p = 0.006) as well as their diameter (LRG 2.1 ± 0.4 mm; HRG 2.4 ± 0.4 mm; univariate: p < 0.001; multivariate: p = 0.006) were highly significantly associated with the development of type 2 endoleaks of the HRG. CONCLUSION The most important predictive factors for the development of high-risk type 2 endoleaks were mainly the number and the diameter of the LAs which perfused the AAA. KEY POINTS • This study is a very detailed and comprehensive analysis of the value of various CT parameters as potential predictors of the clinical outcome of type 2 endoleaks after EVAR. • Anatomical as well as thrombus-specific parameters were unsuitable as predictors. • The most important predictive factors were mainly the number and the diameter of the LAs which perfused the AAA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Renal insufficiency after infrarenal abdominal aortic aneurysm reconstruction: An analysis of this risk factor in 45 patients

 Abstract Background: Renal insufficiency is a potential complication after infrarenal abdominal aortic aneurysm repair and is a significant risk factor for postoperative mortality and morbidity. The aim of this study was to analyze the effect of this risk factor, before and during operation. Methods: In this prospective study, between 2003 and 2006, 45 patients underwent repair of an infrarena...

متن کامل

Frequency of Complications Following Endovascular Repair of Abdominal Aortic Aneurysm in Tehran Sina Hospital, 2011-2019

 Background and purpose: Abdominal aortic aneurysms (AAA) is a localized enlargement of infrarenal abdominal aorta. Endovascular aneurysm repair (EVAR) is a surgical method introduced for AAA repair. This study, for the first time in Iran, investigated the complications and mortality rate associated with EVAR.  Materials and methods: In this cross-sectional study, medical records were reviewed...

متن کامل

An Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess

Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...

متن کامل

Duplex ultrasound and computed tomography angiography in the follow-up of endovascular abdominal aortic aneurysm repair: a comparative study*

OBJECTIVE To compare duplex ultrasound and computed tomography (CT) angiography in terms of their performance in detecting endoleaks, as well as in determining the diameter of the aneurysm sac, in the postoperative follow-up of endovascular abdominal aortic aneurysm repair. MATERIALS AND METHODS This was a prospective study involving 30 patients who had undergone endovascular repair of infrar...

متن کامل

Risk factors for the development of persistent type II endoleaks after endovascular repair of infrarenal abdominal aortic aneurysms.

PURPOSE To determine, based on preoperative imaging findings, which patients treated with endovascular abdominal aneurysm repair are at high risk for the development of persistent type II endoleaks. MATERIALS AND METHODS Preoperative computed tomography (CT) angiographies of 136 patients, treated endovascularly, were retrospectively examined for possible anatomic predictors of type II endolea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin

دوره 187 1  شماره 

صفحات  -

تاریخ انتشار 2015