Effects of dialysate flow configurations in continuous renal replacement therapy on solute removal: computational modeling.
نویسندگان
چکیده
BACKGROUND/AIMS Continuous renal replacement therapy (CRRT) is commonly used for critically ill patients with acute kidney injury. During treatment, a slow dialysate flow rate can be applied to enhance diffusive solute removal. However, due to the lack of the rationale of the dialysate flow configuration (countercurrent or concurrent to blood flow), in clinical practice, the connection settings of a hemodiafilter are done depending on nurse preference or at random. METHODS In this study, we investigated the effects of flow configurations in a hemodiafilter during continuous venovenous hemodialysis on solute removal and fluid transport using computational fluid dynamic modeling. We solved the momentum equation coupling solute transport to predict quantitative diffusion and convection phenomena in a simplified hemodiafilter model. RESULTS Computational modeling results showed superior solute removal (clearance of urea: 67.8 vs. 45.1 ml/min) and convection (filtration volume: 29.0 vs. 25.7 ml/min) performances for the countercurrent flow configuration. Countercurrent flow configuration enhances convection and diffusion compared to concurrent flow configuration by increasing filtration volume and equilibrium concentration in the proximal part of a hemodiafilter and backfiltration of pure dialysate in the distal part. In clinical practice, the countercurrent dialysate flow configuration of a hemodiafilter could increase solute removal in CRRT. Nevertheless, while this configuration may become mandatory for high-efficiency treatments, the impact of differences in solute removal observed in slow continuous therapies may be less important. Under these circumstances, if continuous therapies are prescribed, some of the advantages of the concurrent configuration in terms of simpler circuit layout and simpler machine design may overcome the advantages in terms of solute clearance. CONCLUSION Different dialysate flow configurations influence solute clearance and change major solute removal mechanisms in the proximal and distal parts of a hemodiafilter. Advantages of each configuration should be balanced against the overall performance of the treatment and its simplicity in terms of treatment delivery and circuit handling procedures.
منابع مشابه
Hemodialysis Systems for Intermittent, Semi-Continuous, and Continuous Therapies in Acute Renal Failure.
As is the case in end-stage renal disease (ESRD), both intermittent and continuous renal replacement therapies (RRTs) are employed in acute renal failure (ARF). In fact, a continuum of treatment options is available in ARF. At one end of the ARF RRT spectrum is conventional intermittent hemodialysis (IHD), in which relatively high blood and dialysate flow rates are used (typically ≥250 and 500 ...
متن کاملKinetic Modeling of "Go Slow" Dialysis in Acute Renal Failure.
Go slow" dialysis is a gentle, intermittent hemodialysis therapy for acute renal failure patients, with advantages compared to slow, continuous therapies. It employs a recirculating closed dialysate circuit. A two-pool urea kinetic model is elaborated to determine kinetic parameters from blood and dialysate concentrations. This will allow quantification of the therapy. Variable clearance is inc...
متن کاملLongitudinal hemodiafilter performance in modeled continuous renal replacement therapy.
BACKGROUND/AIMS With advanced anticoagulation, many institutions operate continuous renal replacement therapy (CRRT) circuits longer than manufacturers' recommendations. This extended use may change hemodiafilter performance and clearance properties. However, hemodiafilter performance over time has not been assessed. We investigated solute clearance over time in modeled CRRT. METHODS In vitro...
متن کاملA practical citrate anticoagulation continuous venovenous hemodiafiltration protocol for metabolic control and high solute clearance.
Obstacles to the widespread use of continuous renal replacement therapy (CRRT) include the need for anticoagulation, customized solutions, and complex protocols that carry an attendant risk for error, raise cost, and increase pharmacy and nursing workload. However, high solute clearance using CRRT with an effluent rate of 35 ml/kg per h has also recently been associated with improved survival i...
متن کاملInotropic support and peritoneal dialysis adequacy in neonates after cardiac surgery.
We describe the impact of cardiovascular pharmacologic support on peritoneal dialysis adequacy in 20 neonates who required postoperative renal replacement therapy following cardiopulmonary bypass exposure. Peritoneal dialysis was administered for 2.5 (2) days. Peritoneal dialysis creatinine clearance was 3.4 (2.1) ml/min/1.73 m(2) and ultrafiltration rate was 9.75 (10) ml/h. Residual creatinine...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Blood purification
دوره 35 1-3 شماره
صفحات -
تاریخ انتشار 2013