Characterization of hydromechanical stress in aerated stirred tanks up to 40 m3 scale by measurement of maximum stable drop size

نویسندگان

  • Andreas Daub
  • Marina Böhm
  • Stefanie Delueg
  • Markus Mühlmann
  • Gerhard Schneider
  • Jochen Büchs
چکیده

BACKGROUND Turbulence intensity, or hydromechanical stress, is a parameter that influences a broad range of processes in the fields of chemical engineering and biotechnology. Fermentation processes are often characterized by high agitation and aeration intensity resulting in high gas void fractions of up to 20% in large scale reactors. Very little experimental data on hydromechanical stress for such operating conditions exists because of the problems associated with measuring hydromechanical stress under aeration and intense agitation. RESULTS An indirect method to quantify hydromechanical stress for aerated operating conditions by the measurement of maximum stable drop size in a break-up controlled dispersion was applied to characterize hydromechanical stress in reactor scales of 50 L, 3 m(3) and 40 m(3) volume with a broad range of operating conditions and impeller geometries (Rushton turbines). Results for impellers within each scale for the ratio of maximum to specific energy dissipation rate ϕ based on measured values of maximum stable drop size for aerated operating conditions are qualitatively in agreement with results from literature correlations for unaerated operating conditions. Comparison of data in the different scales shows that there is a scale effect that results in higher values for ϕ in larger reactors. This behavior is not covered by the classic theory of turbulent drop dispersion but is in good agreement with the theory of turbulence intermittency. The data for all impeller configurations and all aeration rates for the three scales can be correlated within ±20% when calculated values for ϕ based on the measured values for dmax are used to calculate the maximum local energy dissipation rate. A correlation of the data for all scales and all impeller configurations in the form ϕ = 2.3∙(ϕunaerated)(0.34)∙(DR)(0.543) is suggested that successfully models the influence of scale and impeller geometry on ϕ for aerated operating conditions. CONCLUSIONS The results show that besides the impeller geometry, also aeration and scale strongly influence hydromechanical stress. Incorporating these effects is beneficial for a successful scale up or scale down of this parameter. This can be done by applying the suggested correlation or by measuring hydromechanical stress with the experimental method used in this study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow Generated by an Aerated Rushton Impeller: Two-phase PIV Experiments and Numerical Simulations

Experiments Most publications of velocity measurements in stirred tanks concern measurements in single-phase flows. An excellent review of these studies was made by Ranade and Joshi (1990a). Literature concerning velocity measurements in aerated stirred tanks is scarcer however. An overview of literature is given in Table 1. Lu and Ju (1987) used constant temperature anemometry (CTA) in order t...

متن کامل

Maximum Stable Drop Diameter in Stirred Dispersions

Transient drop-size distributions of stirred dispersions undergoing breakage were experimentally measured at long stining times. The results show that drops continue to break the entire duration of the experiment (at least up to 10 h) and force a reevaluation of the widely held concept of a maximum stable drop diameter, d,,,. Transient distributions show the existence of self-similarity, which ...

متن کامل

Comparison of mixing between single- and bubbly two-phase systems in a Rushton stirred tank

Mixing is a widely practiced operation to effect distribution, intermingling and homogeneity of matter. Stirred tanks with different geometries (such as in main container tanks, impellers, baffles, etc.) are also widely used to mix different materials. The forces applied by impellers develop overall circulation or bulk flow. Superimposed on this flow pattern, there are turbulent eddies and also...

متن کامل

Bioreactor Scale-up for Water-Gas Shift Reaction

A scale-up study has been performed with three different size reactors to establish the optimum operating conditions for the hydrogen production from synthesis gas by biological water-gas shift reaction using the photosynthetic bacterium Rhodosprilliunt rubrum. Optimum medium composition and operating conditions previously determined in a bench scale 1.25 L continuous stirred tank reactor (CSTR...

متن کامل

بررسی راندمان بیوراکتور دو فازی همزن دار به منظور تصفیه بخارات گزیلن از جریان هوا با بستری از سودوموناس پتیدا

Introduction: Volatile organic compounds such as xylene, which are the main constituents of the oil and petrochemical industries, have serious impacts on health and can cause adverse effects on the environment. It is clear that release of these compounds into the environment should be controlled. The two-phases partitioning stirred tank bio-reactor is one of the newest methods for treating thes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014