Improved T1 mapping with Iterative Actual Flip-angle Imaging (iAFI) Technique
نویسندگان
چکیده
Introduction: Accurate measurement of T1 is essential for many quantitative MRI techniques, such as dynamic contrast enhanced MRI. Variable flip angle (VFA) spoiled gradient echo imaging is one of the most widely used methods for T1 mapping [1]. However, this technique often suffers from flip angle inaccuracies due to inhomogeneous RF fields and slice profile effects [2]. Actual flip-angle imaging (AFI) technique [3] was recently developed to measure the actual flip angle (and equivalently, actual B1) and has been used in conjunction with VFA for improved accuracy [4]. One of the shortcomings of the AFI technique is that the method assumes that T1 is much longer than the repetition time (TR). When this assumption is violated, large errors can result for both the flip angle and T1. We propose an iterative AFI (iAFI) method which yields more accurate T1 values, particularly for relatively short T1s, and which does not require that TR << T1.
منابع مشابه
Accurate and Efficient Mapping of Flip Angle and T1 using Simultaneous Actual Flip Angle - Variable Flip Angle Imaging (AFI-T1)
Introduction: The knowledge of flip angle values is essential for accurate modeling in many quantitative MRI techniques. Recently, Actual Flip Angle Imaging (AFI) was proposed to account for multiple sources of flip angle variations such as transmit field inhomogeneity, B0 variations, slab profile, and excitation pulse effects [1]. AFI was successfully applied to yield system-independent T1 rel...
متن کاملFlip angle-optimized fast dynamic T1 mapping with a 3D gradient echo sequence.
PURPOSE To analyze the flip angle dependence and to optimize the statistical precision of a fast three-dimensional (3D) T1 mapping technique based on the variable flip angle (VFA) method. The proposed single flip angle (1FA) approach acquires only a single 3D spoiled gradient echo data set for each time point of the dynamical series in combination with a longer baseline measurement. THEORY AN...
متن کاملFlip-angle-optimized fast dynamic T1 mapping
Purpose: To analyze the flip-angle dependence and to optimize the statistical precision of a fast three-dimensional T1-mapping technique based on the variable-flip-angle (VFA) method. The proposed single-flip-angle (1FA) approach acquires only a single 3D spoiled gradient-echo data set for each time point of the dynamical series in combination with a longer baseline measurement. Theory and Meth...
متن کاملImproved T1 fitting with the MOLLI sequence
Background T1 mapping has great potential for diagnosing diffuse cardiomyopathies. Modified Look Locker Inversion Recovery (MOLLI) is a promising 2D SSFP technique to measure T1 differences between healthy and diseased states in cardiac tissue. However, this method has been found to provide variable T1 values at different flip angles. Here we develop an improved fitting algorithm which accounts...
متن کاملTransmit B1+ field inhomogeneity and T1 estimation errors in breast DCE-MRI at 3 tesla.
PURPOSE To quantify B1+ variation across the breasts and to evaluate the accuracy of precontrast T1 estimation with and without B1+ variation in breast MRI patients at 3 Tesla (T). MATERIALS AND METHODS B1+ and variable flip angle (VFA) T1 mapping were included in our dynamic contrast-enhanced (DCE) breast imaging protocol to study a total of 25 patients on a 3.0T GE MR 750 system. We compute...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009