Assay of human plasma cortisone by liquid chromatography: normal plasma concentrations (between 8 and 10 a.m.) of cortisone and corticosterone.
نویسندگان
چکیده
A high-performance liquid chromatographic method using ultraviolet detection to quantitate human plasma concentrations of cortisone simultaneously with cortisol and corticosterone is described. The method is based on the use of an octadecyl silica column (100 mm x 2 mm I.D., 3 microns), an ultraviolet absorbance detector (242 nm) with a 10 mm path length flow-cell, and a mobile phase composed of water-tetrahydrofuran-acetonitrile (82:10:8, v/v) containing 5 ml/l triethylamine and citric acid to adjust the pH of the buffer to 6.5. Flumethasone is used as the internal standard. The detection limit of the method for the three steroids is 300 ng/l using a 1-ml sample. The average inter-assay coefficient of variation for cortisone is 3.3% and the average recovery is 100.8%. Possible interferences from common drugs and endogenous and exogenous steroids in the method have been studied. Plasma concentrations (drawn from 8 to 10 a.m.) of cortisone and corticosterone for 43 normal volunteers have been determined.
منابع مشابه
Corticosterone concentrations in the mouse.
The report of Monjan and Collector (1) emphasizes the modulating effects of stress on the immune response in mice. This important and timely contribution strengthens a growing awareness that either intentional or uncontrolled anxietystress in various forms can have critical effects on immunological and pathological reactions in-mice and other experimental animals. There are some technical matte...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملDetermination of Mebudipine in Human Plasma by Liquid Chromatography–tandem Mass Spectrometry
In previous studies, mebudipine, a dihydropyridine calcium channel blocker, showed a considerable potential to be used in cardiovascular diseases. The aim of the current study was to develop a valid method using reversed-phase high performance liquid chromatography coupled with electrospray ionization mass spectrometry to assay mebudipine in the human plasma. Separation was achieved on a Zorbax...
متن کاملDetermination of Mebudipine in Human Plasma by Liquid Chromatography–tandem Mass Spectrometry
In previous studies, mebudipine, a dihydropyridine calcium channel blocker, showed a considerable potential to be used in cardiovascular diseases. The aim of the current study was to develop a valid method using reversed-phase high performance liquid chromatography coupled with electrospray ionization mass spectrometry to assay mebudipine in the human plasma. Separation was achieved on a Zorbax...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of chromatography
دوره 613 2 شماره
صفحات -
تاریخ انتشار 1993