IF Impedance and Mixer Gain of Hot-Electron Bolometers

نویسندگان

  • J. W. Kooi
  • J. J. A. Baselmans
  • J. R. Gao
  • T. M. Klapwijk
  • M. Hajenius
  • P. Dieleman
  • A. Baryshev
  • G. de Lange
چکیده

We have measured the frequency dependent IF impedance and mixer conversion gain of a small area NbN hot-electron bolometer (HEB). The device used is a twin slot antenna coupled NbN HEB mixer with a bridge area of 1 μm x 0.15 μm, and a critical temperature of 8.3 K. In the experiment the local oscillator (LO) frequency was 1.300 THz, and the intermediate frequency (IF) 0.05-10 GHz. We find that the measured data can be described in a self consistent manner with a thin film model presented by Nebosis, Semenov, Gousev, and Renk, that is based on the two temperature electronphonon heat balance equations of Perrin-Vanneste. From these results the thermal time constant, governing the gain bandwidth of HEB mixers, is observed to not only be a function of the electronphonon scattering time and phonon escape time, but also a function of electron temperature. The latter is due to the temperature dependence of the electron and phonon specific heat. Because hot electron bolometers nominally operate at, or slightly above, the critical temperature (Tc) of the superconducting film, where local resistivity as a function of electron temperature is largest, it follows that the critical temperature of the film plays an important role in determining the HEB mixer gain bandwidth. For a NbN based hot electron bolometer, the maximum predicted gain bandwidth is ∼ 5.5 GHz, given a film thickness of 3.5 nm and a Tc=12K.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

IF impedance and mixer gain of NbN hot electron bolometers

The intermediate frequency IF characteristics, the frequency dependent IF impedance, and the mixer conversion gain of a small area hot electron bolometer HEB have been measured and modeled. The device used is a twin slot antenna coupled NbN HEB mixer with a bridge area of 1 0.15 m2, and a critical temperature of 8.3 K. In the experiment the local oscillator frequency was 1.300 THz, and the IF 0...

متن کامل

Characterisation and Modeling of MgB2 HEBs IF impedance

The Terahertz region of the electromagnetic spectrum which offers many molecular and atomic emission is of particular interest for astrophysics [1]. In order to explore the THz frequency band low noise heterodyne receiver are required. Hot electron bolometers (HEB) are the most sensitive THz mixers for frequencies above 1 THz offering a gain bandwidth (GBW) as wide as 4 GHz [2]. HEBs made from ...

متن کامل

Mixing and noise in diffusion and phonon cooled superconducting hot-electron bolometers

We report a systematic, comprehensive set of measurements on the dynamics and noise processes in diffusion and phonon-cooled superconducting hot-electron bolometer mixers which will serve as ultralow noise detectors in THz heterodyne receivers. The conversion efficiency and output noise of devices of varying lengths were measured with radio frequency between 8 and 40 GHz. The devices studied co...

متن کامل

Noise and Conversion Efficiency of Aluminum Superconducting Hot-Electron Bolometer Mixer

We report on microwave measurements of superconducting aluminum hot-electron bolometers (Al HEBs). Diffusion-cooled Al HEB mixers are good candidates for spaceborne applications in the Terahertz frequency range since they are predicted to have small local oscillator (LO) power requirements, intermediate frequency (IF) bandwidths 10 GHz, and a noise temperature lower than that of Nb and NbN HEBs...

متن کامل

Submillimeter-wave spectral response of twin-slot antennas coupled to hot electron bolometers

The spectral response of quasioptical hot-electron bolometer (HEB) mixers has been measured with a Fourier transform spectrometer. In this study we have measured mixers with a wide range of twin-slot antennas with slot lengths ranging from 26 μm up to 152 μm. For all designs, the measured center of the direct detection response was lower than predictions based on a Method-of-Moment (MoM) calcul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005