Impact of prosthesis-patient mismatch on cardiac events and midterm mortality after aortic valve replacement in patients with pure aortic stenosis.

نویسندگان

  • Giordano Tasca
  • Zen Mhagna
  • Silvano Perotti
  • Pietro Berra Centurini
  • Tony Sabatini
  • Andrea Amaducci
  • Federico Brunelli
  • Marco Cirillo
  • Margherita Dalla Tomba
  • Eugenio Quaini
  • Giovanni Troise
  • Philippe Pibarot
چکیده

BACKGROUND Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of the prosthesis being implanted is too small in relation to body size, thus causing abnormally high transvalvular pressure gradients. The objective of this study was to examine the midterm impact of PPM on overall mortality and cardiac events after aortic valve replacement in patients with pure aortic stenosis. METHODS AND RESULTS The indexed EOA (EOAi) was estimated for each type and size of prosthesis being implanted in 315 consecutive patients with pure aortic stenosis. PPM was defined as an EOAi < or =0.80 cm2/m2 and was correlated with overall mortality and cardiac events. PPM was present in 47% of patients. The 5-year overall survival and cardiac event-free survival were 82+/-3% and 75+/-4%, respectively, in patients with PPM compared with 93+/-3% and 87+/-4% in patients with no PPM (P< or =0.01). In multivariate analysis, PPM was associated with a 4.2-fold (95% CI, 1.6 to 11.3) increase in the risk of overall mortality and 3.2-fold (95% CI, 1.5 to 6.8) increase in the risk of cardiac events. The other independent risk factors were history of heart failure, NHYA class III-IV, severe left ventricular hypertrophy, and absence of normal sinus rhythm before operation. CONCLUSIONS PPM is an independent predictor of cardiac events and midterm mortality in patients with pure aortic stenosis undergoing aortic valve replacement. As opposed to other risk factors, PPM may be avoided or its severity may be reduced with the use of a preventive strategy at the time of operation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mid-term impact of patient-prosthesis mismatch on young and middle-aged patients undergoing surgery due to severe aortic stenosis

Methods All patients younger than 70 years of age undergoing isolated aortic valve replacement from October 2005 to October 2011 were analyzed. Patient-prosthesis mismatch was defined as the indexed effective orifice area ≤ 0,85cm2/m2. We studied the impact of patient-prosthesis mismatch on mid-term overall mortality, cardiac events and New York Heart Association functional class using an analy...

متن کامل

Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?

BACKGROUND The study was designed to evaluate the effects of moderate prosthesis-patient mismatch (defined as 0.65 cm(2)/m(2) <indexed effective orifice area ≤ 0.85 cm(2)/m(2)) on midterm outcomes after isolated aortic valve replacement with a 17-mm St. Jude Medical Regent valve in a large series of patients, and to determine if these effects are influenced by patient confounding variables. M...

متن کامل

Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm

Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...

متن کامل

[Influence of patient-prosthesis mismatch in the octogenarian undergoing surgery for aortic valve replacement due to severe stenosis].

INTRODUCTION AND OBJECTIVES The clinical impact of patient-prosthesis mismatch on the outcome in octogenarians who undergo surgery for aortic valve replacement due to severe stenosis is unknown. Our objective was to quantify the frequency of some degree of patient-prosthesis mismatch and its impact on mortality and life quality. METHODS We analyzed all the octogenarian patients who underwent ...

متن کامل

Indexed effective orifice area after mechanical aortic valve replacement does not affect left ventricular mass regression in elderly.

OBJECTIVE After aortic valve replacement, the effects of a small functional prosthesis on the extent and pattern of regression of left ventricular hypertrophy and on clinical outcomes may be less significant in older patients with low cardiac output requirements. The objective of this study was therefore to determine whether patient-prosthesis mismatch affects left ventricular mass regression i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 113 4  شماره 

صفحات  -

تاریخ انتشار 2006