Reliability of Transcutaneous Bilirubin Devices in Preterm Infants: A Systematic Review abstract

نویسندگان

  • Gaurav Nagar
  • Ben Vandermeer
  • Sandra Campbell
  • Manoj Kumar
چکیده

BACKGROUND AND OBJECTIVE: Transcutaneous bilirubin (TcB) devices are widely used for the estimation of serum bilirubin levels in term and near-term infants. Our objective was to review the diagnostic accuracy of TcB devices in preterm infants. METHODS: Medline, Embase, Cochrane library, Cumulative Index to Nursing and Allied Health Literature, and Scopus were searched (from database inception date until December 2012). Additional citations were identified by using the bibliographies of selected articles and from conference proceedings. The studies were included if they compared TcB with total serum bilirubin in preterm infants before phototherapy and presented data as correlation coefficients or as BlandAltman difference plots. Data were extracted by 1 reviewer and checked for accuracy by the second reviewer. An assessment tool (quality assessment of diagnostic accuracy studies) was used for risk of bias assessments. RESULTS: Twenty-two studies met the inclusion criteria; 21 studies reported results as correlation coefficients, with pooled estimates of r = 0.83 for each site of measurement. Pooled estimates in infants ,32 weeks’ gestation were similar to the overall preterm population (r = 0.89 [95% confidence interval: 0.82–0.93]). For the 2 commonly used TcB devices (ie, JM103 and BiliCheck), the results were comparable at the forehead site, although the JM103 device exhibited better correlation at the sternum. Analysis of the BlandAltman plots (13 studies) revealed negligible bias in measurement at the forehead or sternum site by using either the JM-103 or BiliCheck device; however, the JM-103 device exhibited better precision than the BiliCheck (SD for TcB – total serum bilirubin differences: 24.3 and 31.98 mmol/L, respectively). CONCLUSIONS: The TcB devices reliably estimated bilirubin levels in preterm infants and could be used in clinical practice to reduce blood sampling. Pediatrics 2013;132:871–881 AUTHORS: Gaurav Nagar, MD,a Ben Vandermeer, MSc,b Sandra Campbell, MLS,c and Manoj Kumar, MD, MSca aDivision of Neonatology, Department of Pediatrics, bAlberta Research Center for Health Evidence, and cJohn W. Scott Health Sciences Library, University of Alberta, Edmonton, Alberta, Canada

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of transcutaneous bilirubin devices in preterm infants: a systematic review.

BACKGROUND AND OBJECTIVE Transcutaneous bilirubin (TcB) devices are widely used for the estimation of serum bilirubin levels in term and near-term infants. Our objective was to review the diagnostic accuracy of TcB devices in preterm infants. METHODS Medline, Embase, Cochrane library, Cumulative Index to Nursing and Allied Health Literature, and Scopus were searched (from database inception d...

متن کامل

Effect of Phototherapy on the Reliability of Transcutaneous Bilirubin Devices in Term and Near-Term Infants: A Systematic Review and Meta-Analysis.

BACKGROUND Transcutaneous bilirubin (TcB) devices are commonly used for screening of hyperbilirubinemia in term and near-term infants not exposed to phototherapy. However, the accuracy of TcB devices in infants exposed to phototherapy is unclear. OBJECTIVES To conduct a systematic review of studies comparing TcB devices with total serum bilirubin (TSB) in infants receiving phototherapy or in ...

متن کامل

Transcutaneous bilirubinometry: an evaluation.

The transcutaneous bilirubinometer was evaluated in 60 term and 10 preterm infants. A significant correlation was found between the transcutaneous index and the total serum bilirubin concentration for both term and preterm infants. The reliability of the transcutaneous bilirubinometer as a screening method was confirmed, and index criteria for serum bilirubin analysis have been suggested for te...

متن کامل

Archives of Disease in Childhood Fetal and Neonatal Edition 2002;87:F137-F140

TOP ABSTRACT METHODS RESULTS DISCUSSION REFERENCES Background: Two devices are available for making transcutaneous estimates of serum bilirubin (SBR): the Minolta AirShields JM102 and the new SpectRx BiliCheck. Objectives: (a) To measure how well the readings produced by these devices agree with SBR measured in the laboratory; (b) to estimate for each device, the proportion of infants with clin...

متن کامل

Transcutaneous Bilirubinometry in Preterm and Term Newborn Infants before and during Phototherapy.

INTRODUCTION To evaluate the accuracy of transcutaneous bilirubin measurement in a large population of newborn infants, before and during the phototherapy. PATIENTS AND METHODS A single Bilicheck instrument was used for transcutaneous measurements. A photo-opaque patch was positioned over the measurement site prior to starting phototherapy. Transcutaneous bilirubinometry was conducted on an u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013