Seismic Response Reduction of Structures using Smart Base Isolation System
نویسنده
چکیده
In this study, control performance of a smart base isolation system consisting of a friction pendulum system (FPS) and a magnetorheological (MR) damper has been investigated. A fuzzy logic controller (FLC) is used to modulate the MR damper so as to minimize structural acceleration while maintaining acceptable base displacement levels. To this end, a multi-objective optimization scheme is used to optimize parameters of membership functions and find appropriate fuzzy rules. To demonstrate effectiveness of the proposed multi-objective genetic algorithm for FLC, a numerical study of a smart base isolation system is conducted using several historical earthquakes. It is shown that the proposed method can find optimal fuzzy rules and that the optimized FLC outperforms not only a passive control strategy but also a human-designed FLC and a conventional semi-active control algorithm. Keywords—Fuzzy logic controller, genetic algorithm, MR damper, smart base isolation system
منابع مشابه
OPTIMAL SMART BASE ISOLATION SYSTEM FOR MULTIPLE EARTHQUAKES
Hybrid control system composed of a base isolation system and a magneto-rheological damper so-called smart base isolation is one of effective semi-active control system in controlling the seismic response of structures. In this paper, a design method is proposed for designing the smart base isolation system in order to achieve an effective performance under multiple earthquakes. The base mass, ...
متن کاملSeismic Rehabilitation of Liquid Storage Tanks using Friction Pendulum Base Isolation subjected to the Near-Fault Ground Motions
Cylindrical liquid storage tanks are considered as vital structures in industrial complex whose nonlinear dynamic behavior is of crucial importance. Some of these structures around the world have demonstrated poor seismic behavior over the last decades. There are several methods and techniques for rehabilitation and reducing damages in these structures which among them passive control devices, ...
متن کاملApplication of Shape Memory Alloys in Seismic Isolation: A Review
In the last two decades, there has been an increasing interest in structural engineering control methods. Shape memory alloys and seismic isolation systems are examples of passive control systems that use of any one alone, effectively improve the seismic performance of the structure. Characteristics such as large strain range without any residual deformation, high damping capacity, excellent re...
متن کاملEvaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures
The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...
متن کاملEvaluation of the SEAOC/UBC97 Provisions for the Tall Base-Isolated Structures
The base isolation systems are among the passive control devices that have been used over the last three decades to limit the seismic-induced response of structures. In this regard, the Uniform Building Code provisions (UBC) has incorporated a special section for the seismic design of base isolated structures since its 1991 edition. Due to the importance of the behavior of these structures unde...
متن کاملEvaluation of TLD Performance in Reducing the Seismic Response of Structures
Tuned Liquid Dampers (TLD) are among passive control devices that have been used to suppress the vibration of structures in recent years. These structures must be adequately presentable as an equivalent single degree of freedom system with long fundamental period. The TLD, located at the top floors of the structure, can dissipate the external input energy into the system through the sloshing ef...