Intravascular ultrasound cross-sectional arterial imaging before and after balloon angioplasty in vitro.
نویسندگان
چکیده
A prototype ultrasound imaging catheter was evaluated in vitro using 17 human atherosclerotic artery segments before and after balloon dilatation angioplasty. The catheter was 1.2 mm in diameter and incorporated a single 20-MHz ultrasound transducer to obtain cross-sectional images of the arterial lumen. In 15 of the 17 (88%) arteries, high quality images were obtained, which demonstrated clear demarcation between the lumen and the endothelium, the atheroma plaque, the muscular media, and the adventitia. Qualitative characteristics of plaque disruption, dissection, and residual flaps were readily visible. In addition, quantitative information about cross-sectional lumen area was obtained before and after balloon dilatation. The mean cross-sectional lumen area increased from 8.7 to 15.1 mm2 (p less than 0.01) following balloon dilatation. The lumen area measured from the ultrasound images following dilatation correlated closely with the area measured from histologic sections (r = 0.88). The results from this study indicate that a small-diameter ultrasound imaging catheter can be developed that will provide high-resolution qualitative and quantitative information during peripheral and coronary angioplasty.
منابع مشابه
Intravascular ultrasound imaging of human coronary arteries in vivo. Analysis of tissue characterizations with comparison to in vitro histological specimens.
BACKGROUND Intravascular ultrasound imaging was performed in 27 patients after coronary balloon angioplasty to quantify the lumen and atheroma cross-sectional areas. METHODS AND RESULTS A 20-MHz ultrasound catheter was inserted through a 1.6-mm plastic introducer sheath across the dilated area to obtain real-time images at 30 times/sec. The ultrasound images distinguished the lumen from ather...
متن کاملSerial Analysis of Human Iliac Arteries Using Intravascular Ultrasound
Background. Previous studies regarding the mechanism by which balloon angioplasty increases luminal patency have generally used animal models or postmortem specimens from occasional fatal cases of angioplasty performed in human patients. In either case, conclusions regarding participatory mechanisms have relied exclusively on nonserial, postangioplasty histopathological examination. Methods and...
متن کاملAn Observational Study Using Intravascular Ultrasound
Background. Atherosclerotic plaque fracture and dissection of the arterial wall are frequent concomitants of the balloon angioplasty process. The composition and morphology of plaque within the vessel may be critical in determining the extent of plaque fracture and dissection during balloon angioplasty. To examine this potential association in the clinical setting, we studied patients with intr...
متن کاملMorphological effects of coronary balloon angioplasty in vivo assessed by intravascular ultrasound imaging.
BACKGROUND Histological examination of the effects of balloon angioplasty have been described from in vitro experiments and a limited number of pathologic specimens. Intravascular ultrasound imaging permits real time cross-sectional observation of the effect of balloon dilation on the atherosclerotic plaque in vivo. METHODS AND RESULTS The morphological effects of coronary angioplasty were vi...
متن کاملCatheter for Percutaneous Transluminal Angioplasty Validation of Imaging, Analysis of Recoil, and Identification of Plaque Fracture
Background. We investigated the hypothesis that an ultrasound transducer positioned within an angioplasty balloon could be used to perform quantitative assessment of arterial dimensions before and after percutaneous transluminal angioplasty (PTA) and to identify certain mechanical alterations consequent to PTA, including vascular wall recoil and the initiation of plaque fractures. Methods and R...