Screening for interference in immunoassays.
نویسندگان
چکیده
BACKGROUND The presence of interfering substances in patient samples submitted for immunoassay cannot be reliably anticipated. We therefore evaluated three interference screening techniques and estimated the prevalence of interfering substances as defined by positive outcomes with these protocols. METHODS We evaluated 160 samples for the presence of substances that may interfere with four immunoassays (40 samples for each): thyroid-stimulating hormone, prostate-specific antigen, beta-human chorionic gonadotropin, and cortisol. Interference was defined by nonlinear responses with serial dilution, discrepant results after pretreatment with heterophile blocking reagent (HBR), and positive reactions on a mouse-antibody-negative control reaction (Tandem ICON ImmunoConcentration HCG). Criteria for declaring significant discrepant results were based on a Z-score computed using the assay CV. The McNemar test was used to compare the prevalence of discrepancies across the three screening techniques. The association between type of immunoassay and prevalence of discrepant results was determined by a modified Pearson chi(2) statistic. RESULTS Five of the 160 samples [3.1%; 95% confidence interval (CI), 1.0-7.1%] screened positive with the ICON. Seventy-two of the 148 samples with informative serial dilutions (48.6%; 95% CI, 40.4-57.0%) had at least one discrepant result at higher dilutions. After pretreatment with HBR, 53 of the 140 samples (38%; 95% CI, 29.8-46%) were discrepant. Only 48 of the 140 samples with informative measurements for all three screening techniques (34%; 95% CI, 26-43%) were negative by all three. The prevalence of positive screens varied significantly by type of immunoassay (P <0.0001) for both HBR and serial dilution. Only 3% (0.8-7%) of the samples tested with HBR showed a change from normal to abnormal or the reverse after treatment. CONCLUSIONS Introducing a protocol based on any of these three techniques into the immunochemistry laboratory to prescreen for interfering substances is not warranted. The evaluation of specimens for the presence of interfering anti-animal antibodies should be reserved for cases in which clinical history or suspicious results indicate the need.
منابع مشابه
The Risk from Anti-Thyroid Hormone Antibody Interference in Neonatal Congenital Hypothyroidism Screening
Neonatal congenital hypothyroidism screening is considered to be one of the most effective newborn screening strategies. Neonatal screening for congenital hypothyroidism involves the analysis of thyroid hormone and thyrotropin levels using an immunoassay based technique. Immunoassays are also prone to analytical problems such as assay interference. Immunoassays used for thyroid hormone measurem...
متن کاملHeterophilic antibody interference in commercial immunoassays; a screening study using paired native and pre-blocked sera.
BACKGROUND Heterophilic antibodies are still an important source of interference in immunoassays. We have conducted a screening study for interference in a panel of commercially available assays using two sera known to contain high titer Fc-reactive heterophilic antibodies. METHODS The sera were distributed to laboratories participating in the Nordic External Quality Assessment cooperation (E...
متن کاملPositive interference in Radioimmunoassay determination of serum total T3
Introduction: Determination of thyrotropin, total and free thyroxine and triiodothyronine are widely used as diagnostic methods for thyroid function evaluation. There have been numerous reports of interferences in thyroid hormone immunoassays. Herein, a prominent positive interference is reported for a radioimmunoassay kit of total triiodothyronine. Materials and Methods: In this study, a total...
متن کاملEffect of piperacillin-tazobactam on clinical capillary zone electrophoresis of serum proteins.
immunoassay, whereas the Syva and Genix assays are one-step immunochromatographic assays for rapid detection of opiates in urine with a cutoff concentration of 300 mg/L. Information about rifampin cross-reactivity with these immunoassays was not available from the manufacturers. The only reported interference for rifampin is with the opiates kinetic interaction of microparticles in solution (KI...
متن کاملEfavirenz interference in urine screening immunoassays for tetrahydrocannabinol.
BACKGROUND It has been known for some time that the antiretroviral drug, efavirenz (EFV), cross-reacts in urine immunoassays for tetrahydrocannabinol (THC). Because published studies investigating this phenomenon are limited, cross-reactivity information for several immunoassays is lacking. Reports of possible false-positive THC results from clinicians conducting workplace testing prompted us t...