Iterative image reconstruction for CBCT using edge-preserving prior.
نویسندگان
چکیده
On-board cone-beam computed tomography (CBCT) is a new imaging technique for radiation therapy guidance, which provides volumetric information of a patient at treatment position. CBCT improves the setup accuracy and may be used for dose reconstruction. However, there is great concern that the repeated use of CBCT during a treatment course delivers too much of an extra dose to the patient. To reduce the CBCT dose, one needs to lower the total mAs of the x-ray tube current, which usually leads to reduced image quality. Our goal of this work is to develop an effective method that enables one to achieve a clinically acceptable CBCT image with as low as possible mAs without compromising quality. An iterative image reconstruction algorithm based on a penalized weighted least-squares (PWLS) principle was developed for this purpose. To preserve edges in the reconstructed images, we designed an anisotropic penalty term of a quadratic form. The algorithm was evaluated with a CT quality assurance phantom and an anthropomorphic head phantom. Compared with conventional isotropic penalty, the PWLS image reconstruction algorithm with anisotropic penalty shows better resolution preservation.
منابع مشابه
Iterative total-variation reconstruction versus weighted filtered-backprojection reconstruction with edge-preserving filtering.
Iterative image reconstruction with the total-variation (TV) constraint has become an active research area in recent years, especially in x-ray CT and MRI. Based on Green's one-step-late algorithm, this paper develops a transmission noise weighted iterative algorithm with a TV prior. This paper compares the reconstructions from this iterative TV algorithm with reconstructions from our previousl...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملStatistical Methods for Transmission Image Reconstruction with Nonlocal Edge-Preserving Regularization
Statistical Methods for Transmission Image Reconstruction with Nonlocal Edge-Preserving Regularization
متن کاملEdge-Enhanced Image Reconstruction Using (TV) Total Variation and Bregman Refinement
We propose a novel image resolution enhancement method for multidimensional images based on a variational approach. Given an appropriate downsampling operator, the reconstruction problem is posed using a deconvolution model under the assumption of Gaussian noise. In order to preserve edges in the image, we regularize the optimization problem by the norm of the total variation of the image. Addi...
متن کاملI. INTRODUCTION Advances in model-based iterative reconstruction (IR) methods for x-ray CT and cone-beam CT (CBCT) imaging
C-arm cone-beam CT offers great potential in image-guided interventions, but conventional analytic reconstruction methods are associated with limited image quality, particularly for soft-tissue imaging. While model-based iterative reconstruction (IR) methods improve image quality and/or reduce radiation dose, long reconstruction time limits utility in clinical workflow. Additionally, in contras...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 36 1 شماره
صفحات -
تاریخ انتشار 2009