Panel Session on Data for Modeling System Transients Determination of Rotating Machine Parameters for Transients Simulations
نویسنده
چکیده
A rotating machine is a very complex device that involves electrical, mechanical and control systems. Therefore, the whole representation of a machine requires the specification of electrical and mechanical parameters, as well as control system data. The representation of the mechanical part and the control systems are only needed for low frequency transients [1]. An accurate representation of the mechanical part is important for some specific studies, such us torsional oscillations (subsynchronous resonance SSR), transient torques or turbine-blade vibrations [2]. For a discussion on this subject see [1], [3] – [7]. This presentation is related to the determination of electrical parameters of ac rotating machines. They are usually obtained in one of the following forms : • data supplied by manufacturers (conventional stability format data, standstill frequency response), • data from field tests (on-line frequency response, load rejection test, other tests), • computer calculations, using for instance the finite-element method [7].
منابع مشابه
Fault location and classification in non-homogeneous transmission line utilizing breaker transients
In this paper, a single-ended fault location method is presented based on a circuit breaker operation using the frequencies of traveling waves. The proposed method receives the required data from voltage traveling waves with the aid of Fast Fourier Transform (FFT) and Wavelet Transform. Then, the Artificial Neural Network (ANN) identifies fault type and determines its location. In order to eval...
متن کاملTransient Minimization Within Static Var Compensated Distribution Systems
VAR support should be supplied as close to the load as possible to minimize transmission losses. For voltage control and for improvement of total power factor in a distribution system the circuit- breaker switched capacitor banks can be used. The problems with this solution are the voltage steps caused by the large sizes of the capacitor banks as well as the transients caused on insertion. Thyr...
متن کاملFlow Seals Parameters Analysis For Rotors
The interaction of work fluid mechanics with that of the rotary system itself, basically composed of axes, bearings and rotors, is performed by inserting equivalent dynamic coefficients in the mathematical model of the rotor, the latter being obtained by the finite element method. In this paper, the dynamic coefficients of inertia, stiffness and damping of the flat seals analyzed here are evalu...
متن کاملEffect of Machine Parameters on Starting Transients of Grid Connected Induction Generators used in
Induction generators (IGs) are becoming important day by day in wind energy conversion. As such the numbers of IGs in a power system are increasing hence posing power quality problems. When large numbers of IGs are switched on or switched off from a circuit give rise to transients in the power system. In this paper authors tried to explore the effect of machine parameters on starting transients...
متن کاملPanel Session on Data for Modeling System Transients Insulated Cables
The available EMTP-type programs have dedicated support routines (Cable Constants) for calculating an electric representation of cable systems in terms of a series impedance matrix Z and a shunt admittance matrix Y, based on cable data defined by geometry and material properties. Z and Y are then used as the basic input for the various cable models applied in time domain transient simulations. ...
متن کامل