Evaluation of the API 20E system for identification of nonfermentative Gram-negative bacteria.

نویسندگان

  • M Shayegani
  • P S Maupin
  • D M McGlynn
چکیده

The API 20E system for Enterobacteriaceae, recently broadened to include identification of nonfermentative gram-negative bacteria, was evaluated and compared with the conventional method for complete identification of 221 nonfermenters, which were well distributed into 48 species or biotypes and included organisms not listed in the API 20E data base. The results of 16 tests common to both systems were in close agreement. The API 20E system correctly identified 71 (43%) of the 165 organisms included in the API 20E data base. However, almost 90% of Acinetobacter calcoaceticus, three species of Pseudomonas, and Bordetella bronchiseptica were correctly identified to species.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the API 20E and Oxi/Ferm systems in identification of nonfermentative and oxidase-positive fermentative bacteria.

The API 20E and Oxi/Ferm systems were tested in parallel to identify nonfermentative bacteria and oxidase-positive fermentative bacteria. Test strains consisted of consecutive clinical isolates, with stock cultures used to supplement those species infrequently recovered. The two microsystems, as well as tubes of triple sugar iron, motility, cetrimide, and oxidative glucose media, were inoculate...

متن کامل

Evaluation of Cathra system for identifying gram negative aerobic bacteria.

The Cathra system is a commercial multipoint inoculation method for the identification of aerobic Gram negative bacteria. The system uses a replicator technique in which 21 different agar media can be inoculated simultaneously with 36 organisms. Identifications are made by use of a special computer database. The performance of this system was compared with that of the API 20E for the identifica...

متن کامل

The applicability of the API 20E and API Rapid NFT systems for the identification of bacteria from activated sludge

The purpose of this study was to test the applicability of the API 20E and API Rapid NFT systems for the identification of some predominant gram-negative and gram-positive bacteria isolated from lab-scale activated sludge treatment systems. In this study, one lab-scale sequencing batch reactor (SBR) and one lab-scale continuous-flow stirred tank reactor (CFSTR) were setup. After both reactors h...

متن کامل

The comparison of PCR technique and API-20E kit with the conventional biomedical methods for the identification of Salmonella species in laboratory

Abstract Bachground and objectives: Salmonella is one of the most important agents of gastrointestinal infection and diarrhea in our country. Misdiagnosis of these bacteria leads to cure failure. The aim of this study was to make a comparison between PCR and the API-20E and conventional biochemical tests carried out for the identification of Salmonella. Material and Methods: In this study 470 s...

متن کامل

Comparison of identifications of human and animal source gram-negative bacteria by API 20E and crystal E/NF systems.

This study compared the abilities of API 20E and BBL Crystal E/NF identification systems to correctly identify human and animal source gram-negative bacilli of known identifications, as provided by the American Type Culture Collection, Rockville, Md., and the Research Diagnostic and Investigative Laboratory, Columbia, Mo. Also addressed in the comparison are the cost, the relative ease of perfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 7 6  شماره 

صفحات  -

تاریخ انتشار 1978