A novel thermal compression device for perioperative warming: a randomized trial for feasibility and efficacy

نویسندگان

  • Peter Luke Santa Maria
  • Chloe Santa Maria
  • Andreas Eisenried
  • Nathalia Velasquez
  • Brian Thomas Kannard
  • Abhinav Ramani
  • David Mark Kahn
  • Amanda Jane Wheeler
  • John Gerhard Brock-Utne
چکیده

BACKGROUND Inadvertent perioperative hypothermia (IPH) leads to surgical complications and increases length of stay. IPH rates are high with the current standard of care, forced air warming (FAW). Our hypothesis is that a prototype thermal compression device that heats the popliteal fossa and soles of the feet, with lower leg compression, increases perioperative temperatures and reduces IPH compared to the current standard of care. METHODS Thirty six female breast surgery patients, at a tertiary academic hospital, were randomized to the device or intraoperative FAW (stage I) with a further 18 patients randomized to the device with a single heating area only (stage II, popliteal fossa or sole of the feet). Stage I: 37 patients recruited (final 36). Stage II: 18 patients recruited (final 18). INCLUSION CRITERIA general anesthesia with esophageal monitoring for over 30 min, legs available and able to fit the device and no contraindications to leg heating or compression. The intervention was: Stage I: Investigational prototype thermal compression device (full device group) or intraoperative FAW. Stage II: Device with only a single heating location. Primary outcomes were perioperative temperatures and incidence of IPH. Secondary outcomes were local skin temperature, general and thermal comfort scores and presence of perioperative complications, including blood loss. RESULTS Mean temperatures in the full device group were significantly higher than the FAW group in the pre-operative (36.7 vs 36.4 °C, p < 0.001), early intraoperative (36.3 vs 35.9 °C, p < 0.001), intraoperative (36.6 vs 36.2 °C, p < 0.001) and postoperative periods (36.8 vs 36.5 °C, p < 0.001). The incidence of IPH in the device group was also significantly lower (16.7% vs 72.0%, p = 0.001). Thermal comfort scores were significantly higher in the full device group and hypothermia associated wound complications were higher in the FAW group. CONCLUSIONS The thermal compression device is feasible and has efficacy over the FAW. Further studies are recommended to investigate clinically significant outcomes. TRIAL REGISTRATION clinicaltrials.gov ( NCT02155400 ).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preventing hypothermia in elective arthroscopic shoulder surgery patients: a protocol for a randomised controlled trial

BACKGROUND Patients having arthroscopic shoulder surgery frequently experience periods of inadvertent hypothermia. This common perioperative problem has been linked to adverse patient outcomes such as myocardial ischaemia, surgical site infection and coagulopathy. International perioperative guidelines recommend patient warming, using a forced air warming device, and the use of warmed intraoper...

متن کامل

The Effect of Warm Compression Applied before Heel Lance on Pain Level, Comfort Level and Procedure Time in Healthy Term Newborns: A Randomized Clinical Trial

Background & aim: Warm compression is an effective method preferred in relieving pain. It enables procedures to be completed in a shorter time, and with less pain due to increasing blood flow in the area. This study aimed to investigate the effects of warm compress applied before heel lance on the procedure time, level of pain, and comfort level of healthy term newborn...

متن کامل

Meta-analysis: effectiveness of forced-air warming for prevention of perioperative hypothermia in surgical patients.

AIM The aim of this study was to evaluate the effectiveness of forced-air warming for preventing perioperative hypothermia. BACKGROUND Perioperative hypothermia commonly occurs in patients receiving anaesthesia during surgeries. However, the effectiveness of warming systems requires verification. DESIGN Systematic review incorporating meta-analysis. DATA SOURCES We searched OVID, PubMed, ...

متن کامل

Benefits of intraoperative skin surface warming in cardiac surgical patients.

We have investigated patients undergoing cardiac surgery with hypothermic bypass to see if the addition of skin surface warming during systemic rewarming on bypass (heated group, n = 43) would improve perioperative thermal balance compared with conventional management without skin warming (control group, n = 43) in an open, randomized, controlled study. Intraoperative skin warming with a water ...

متن کامل

Prevention of hypothermia in patients undergoing orthotopic liver transplantation using the humigard® open surgery humidification system: a prospective randomized pilot and feasibility clinical trial

BACKGROUND Perioperative thermal disturbances during orthotopic liver transplantation (OLT) are common. We hypothesized that in patients undergoing OLT the use of a humidified high flow CO2 warming system maintains higher intraoperative temperatures when compared to standardized multimodal strategies to maintain thermoregulatory homeostasis. METHODS We performed a randomized pilot study in ad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017