[Examination of three-detector high-speed-rotation SPECT acquisition under breathhold in body: clinical application of 99mTc-MAA].

نویسندگان

  • Yona Oishi
  • Hideyuki Iwanaga
  • Kazuyoshi Suga
  • Ryoko Ide
  • Akiyo Shimizu
  • Akira Inoue
  • Masahiro Koike
چکیده

In traditional pulmonary perfusion single photon emission computed tomography (SPECT), respiratory lung motion and cyclically varying changes in lung volume during image acquisition inherently degrade the image sharpness of ill-defined perfusion defects. However, because of the lack of an adequate fast imaging technique, perfusion SPECT has never been acquired under breathhold conditions, whereas breathhold images are commonly used for pulmonary magnetic resonance (MR) and computed tomographic (CT) images. Although a high-speed imaging technique combined with a multidetector SPECT system may enable SPECT images to be obtained during a short period of breathholding, image quality would be degraded owing to decreased radioactivity counts and increased statistical noise. To resolve this problem, we developed an innovative SPECT imaging technique using a triple-head SPECT system and the high-speed-detector rotation-multiplied projection (HSRMP) technique, where a single SPECT image was reconstructed from multiple respiratory dimensional breathhold projection data obtained at the same angle. HSRMP provided noiseless high-quality perfusion SPECT images by compensating for decreased radioactivity counts caused by high-speed imaging, and significantly improved image quality and perfusion defect clarity compared with traditional non-breathhold SPECT images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual radioisotopes simultaneous SPECT of 99mTc-tetrofosmin and 123I-BMIPP using a semiconductor detector.

Objective(s): The energy resolution of a cadmium-zinc-telluride (CZT) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional Anger type detector which is 10%. Also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. In this study, we used a semiconductor detector and examined the ef...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Preclinical evaluation of 68Ga-MAA from commercial available 99mTc-MAA kit

99mTc-Macroaggregated Albumin (99mTc-MAA) has been used as a perfusion agent. This study described development of the 68Ga-MAA via commercially available kits from Pars-Isotopes Company as a 99mTc-MAA kit. 68Ge/68Ga generator was eluted with suprapure HCl (0.6 M, 6 mL) in 0.5 mL fractions. The two fractions with the highest 68GaCl3 activity were generally used for labeling purposes. After label...

متن کامل

Preclinical evaluation of 68Ga-MAA from commercial available 99mTc-MAA kit

99mTc-Macroaggregated Albumin (99mTc-MAA) has been used as a perfusion agent. This study described development of the 68Ga-MAA via commercially available kits from Pars-Isotopes Company as a 99mTc-MAA kit. 68Ge/68Ga generator was eluted with suprapure HCl (0.6 M, 6 mL) in 0.5 mL fractions. The two fractions with the highest 68GaCl3 activity were generally used for labeling purposes. After label...

متن کامل

Evaluation of Simultaneous Dual-radioisotope SPECT Imaging Using 18F-fluorodeoxyglucose and 99mTc-tetrofosmin

Objective(s): Use of a positron emission tomography (PET)/single-photonemission computed tomography (SPECT) system facilitates the simultaneousacquisition of images with fluorine-18 fluorodeoxyglucose (18F-FDG) andtechnetium (99mTc)-tetrofosmin. However, 18F has a short half-life, and 511keV Compton-scattered photons are detected in the 99mTc energy window.Therefore, in this study, we aimed to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nihon Hoshasen Gijutsu Gakkai zasshi

دوره 62 2  شماره 

صفحات  -

تاریخ انتشار 2006