Predictors of restenosis after coronary stent implantation.
نویسندگان
چکیده
OBJECTIVES We sought to determine predictors of restenosis after coronary stenting (CS) in a consecutive series of patients. BACKGROUND Although stenting in highly selected patient groups reduces restenosis, the results of stenting in a heterogeneous patient group and the effects of clinical and procedural factors on stent restenosis are currently unclear. METHODS We analyzed the 6-month angiographic outcome of 500 lesions in 463 consecutive patients undergoing successful CS. Clinical, qualitative and quantitative angiographic variables were correlated with restenosis assessed as both a binary and a continuous variable. RESULTS Restenosis, defined as the presence of >50% diameter stenosis in the dilated segment, was present in 105 (26%) of the 405 lesions with angiographic follow-up. The mean late lumen loss during the follow-up period was 0.79+/-0.64 mm. Implantation of multiple stents (p < 0.0001) and a high acute gain (p < 0.0002) were independently associated with a higher late lumen loss. In contrast, the use of high inflation pressure (p < 0.02) and Palmaz-Schatz stents (p < 0.005) was independently associated with a lower late lumen loss. When restenosis was defined as a qualitative variable, implantation of multiple stents (p < 0.001), stenosis length (p < 0.01), small reference diameter (p < 0.02) and stent type other than Palmaz-Schatz (p < 0.01) were independent predictors of restenosis. None of the clinical variables tested was associated with restenosis. CONCLUSIONS Coronary stenting in an unselected patient group is associated with an acceptable restenosis rate. Although some risk factors were identified, the risk of restenosis was not related to most of the variables tested. This suggests that the superiority of CS over balloon angioplasty, in terms of restenosis, might also apply to subgroups of patients that were not included in the recent randomized studies.
منابع مشابه
Predictors of restenosis after implantation of 2.5 mm stents in small coronary arteries.
BACKGROUND The results of stent implantation for small coronary disease have been inconclusive. The purpose of the present study was to evaluate the factors in predicting the risk of angiographic restenosis after 2.5-mm stent implantation for small coronary arteries. METHODS AND RESULTS The study group comprised 134 consecutive patients who had a reference small coronary artery with diameter ...
متن کاملIntravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation.
AIMS In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation. METHODS AND RESULTS SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-mon...
متن کاملApplication of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...
متن کاملReference chart derived from post-stent-implantation intravascular ultrasound predictors of 6-month expected restenosis on quantitative coronary angiography.
BACKGROUND Intravascular ultrasound (IVUS)-guided stent implantation and the availability of a reference chart to predict the expected in-stent restenosis rate based on operator-dependent IVUS parameters may interactively facilitate optimal stent placement. The use of IVUS guidance protects against undue risks of dissection or rupture. METHODS AND RESULTS IVUS-determined post-stent-implantati...
متن کاملSafety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کامل[Previous restenosis as a prognostic indicator in new conventional stent implantation at a different location].
INTRODUCTION AND OBJECTIVES The aim was to determine whether data on restenosis of a previous stent are useful for predicting outcome in patients who need to undergo a second conventional stent implantation at a different location because of coronary disease progression. METHODS The study included 80 patients who, during 2000-2004, underwent a second conventional (i.e., not drug-eluting) sten...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American College of Cardiology
دوره 31 6 شماره
صفحات -
تاریخ انتشار 1998