Transient evoked otoacoustic emissions (TEOAEs) in new-borns: normative data.
نویسندگان
چکیده
OBJECTIVE Early diagnosis and rehabilitation of congenital hearing loss are mandatory in order to achieve a satisfactory linguistic and cognitive development. A universal hearing screening in order to identify congenital hearing losses before 3 months of age is required. METHODS TEOAEs are an easy to perform, short lasting, not invasive and low-cost test with a high sensitivity. 320 at term new-borns (640 ears) without any risk factor for hearing loss underwent TEOAEs. The new-borns were screened 3 days after birth. Those who failed the first test were retested when possible before the discharge from the hospital. ABR was performed 3 months later in cases who failed TEOAE. RESULTS The median TEOAE sampling time was 98 s, the median test duration was 14 min. The mean stimulus amplitude was 80 dB peSPL in the left ear and 81 dB peSPL in the right ear, noise levels within the external meatus during sampling were 44 dB SPL on the right ear and 43 dB SPL on the left one, noise contained within the response (A-B difference) was 8.65 dB SPL in the left ear and 8.74 dB SPL in the right ear, mean TEOAEs amplitudes were 21.49 dB SPL and 21.78 dB SPL in the right and left ear respectively, the mean lower and upper limit of the spectrum being 678 and 5720 Hz. According to these criteria 494/640 ears (77.2%) passed the test at the first recording, while TEOAEs resulted to be absent in 146/640 ears (22.8%). A retest was performed successfully before the discharge from the Hospital in 30/640 ears (4.7%). An ABR recording within the third month of life was scheduled as out-patient in the 58 new-borns (116 ears, 18.2%) who failed the test. 18 of them (36 ears, 5.6%) did not complete the program, 19 new-borns (38 ears, 11.8%) showed a normal ABR, while two new-borns (four ears, 0.6%) failed ABR after 3 months. A second ABR performed after 6 months was normal. CONCLUSIONS TEOAEs recording seems at now the test of choice for a universal hearing screening. However, a greater standardization of criteria both in performing the test and in evaluating the results is needed.
منابع مشابه
Clinical observations with evoked otoacoustic emissions at Mayo Clinic.
Clinical applications of transient evoked otoacoustic emission (TEOAE) measures began in 1989 at Mayo Clinic Rochester. Normative data indicates: a) greater TEOAE level for women and right ears beginning in the teen years, b) mean TEOAE levels remain relatively stable through the first seven decades of life, c) between subject EOAE level variability for normal hearing adults is high (up to abou...
متن کاملTransient evoked otoacoustic emissions and pseudohypacusis.
The audiologic diagnosis of pseudohypacusis continues to challenge the clinical audiologist. The introduction of otoacoustic emissions (OAEs) to the test repertoire of the audiologist may prove valuable in the evaluation of pseudohypacusis. This report highlights five cases in which transient evoked otoacoustic emissions (TEOAEs) were used to cross-check the validity of subjective audiologic th...
متن کاملThe relationship between ultra-high frequency thresholds and transient evoked otoacoustic emissions in adults with tinnitus
Background: The possible role of cochlear function in tinnitus generation is still a matter of debate. To assess the role of outer hair cell dysfunction in tinnitus and its possible relationship with ultra-high frequency (UHF) hearing sensitivity, transient evoked otoacoustic emissions (TEOAE) and UHF hearing thresholds were investigated in normal hearing individuals with and withou...
متن کاملSex differences in distortion-product and transient-evoked otoacoustic emissions compared.
Although several studies have documented the existence of sex differences in spontaneous otoacoustic emissions (SOAEs) and transient-evoked OAEs (TEOAEs) in humans, less has been published about sex differences in distortion-product OAEs (DPOAEs). Estimates of sex and ear differences were extracted from a data set of OAE measurements previously collected for other purposes. In accord with past ...
متن کاملReproducing Cochlear Signals by a Minimal Electroacoustic Model
Transient-Evoked Otoacoustic Emissions (TEOAEs) were studied, with particular reference to their subject-dependent features. To this end, an electric model of the ear was implemented and validated. Simulated and natural TEOAEs were analyzed through a nonlinear analysis technique. The simulated signals were able to reproduce the dynamical features of the experimentally observed TEOAEs and, most ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of pediatric otorhinolaryngology
دوره 47 3 شماره
صفحات -
تاریخ انتشار 1999