γ-ray measurements and neutron sensitivity in a fusion environment

نویسندگان

  • M. Nocente
  • M. Angelone
  • P. Blanchard
  • C. Cazzaniga
  • I. Chugunov
  • G. Croci
  • D. Gin
  • G. Grosso
  • V. G. Kiptily
  • A. Neto
  • A. Olariu
  • S. Olariu
  • R. C. Pereira
  • M. Pillon
  • A. Shevelev
  • J. Sousa
  • D. B Syme
  • M. Tardocchi
  • G. Gorini
چکیده

A system based on a LaBr3(Ce) scintillator and digital data acquisition is discussed in view of γ-ray spectroscopy measurements on a fusion burning plasma. High energy resolution and high rate capability of the system are demonstrated in laboratory tests and in dedicated experiments at nuclear accelerators. Preliminary results on sensitivity of the detector to 14 MeV neutrons are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modification of 10 cGy neutron or gamma-rays induced chromosomal damages by hyperthermia: an in vitro study

Background: To evaluate the effects of hyperthermia (HT) on the frequency of chromosomal aberrations induced by a low dose of neutron or γ-rays in human peripheral blood lymphocytes. Materials and Methods: Blood samples were exposed to HT (41.5°C for 30 and 60min, 43°C for 15 and 30min), 10 cGy neutron or γ-rays, HT + neutron/γ, and neutron/γ + HT. After standard cell culture, harvestin...

متن کامل

Shielding studies on a total-body neutron activation facility

Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. 252Cf and 241Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwa...

متن کامل

Response of LaBr3(Ce) scintillators to 2.5 MeV fusion neutrons.

Measurements of the response of LaBr3(Ce) to 2.5 MeV neutrons have been carried out at the Frascati Neutron Generator and at tokamak facilities with deuterium plasmas. The observed spectrum has been interpreted by means of a Monte Carlo model. It is found that the main contributor to the measured response is neutron inelastic scattering on (79)Br, (81)Br, and (139)La. An extrapolation of the co...

متن کامل

Polymethylmethacrylate/Silver Nanocomposite Prepared by γ-Ray

Polymethylmethacrylate-silver (PMMA/Ag) nanocomposite is synthesized by irradiating the solution of silver ions in methylmethacrylate monomer by γ-ray. In this method, polymerization of the methylmethacrylate monomer and the silver ion reduction occurred simultaneously. Optical properties of the PMMA/Ag solutions are investigated using UV-Vis spectroscopy. The structural characterizations of th...

متن کامل

A Current Mode Detector Array for Gamma-Ray Asymmetry Measurements

We have built a CsI(Tl) γ-ray detector array for the NPDGamma experiment to search for a small parity-violating directional asymmetry in the angular distribution of 2.2 MeV γ-rays from the capture of polarized cold neutrons by protons with a sensitivity of several ppb. The weak pion-nucleon coupling constant can be determined from this asymmetry. The small size of the asymmetry requires a high ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012