PURPOSE To evaluate incidence and risk factors for corneal hydration intra-operatively during phacoemulsification (CHIP). METHODS AND MATERIALS This was a randomised, clinical trial, where 240 eyes of 240 patients with senile cataracts undergoing phacoemulsification were prospectively randomised to receive one of three possible types of incision architecture - single, two or three planes. Viscoelastic injection through paracentesis, before instruments were withdrawn from the main incision, was randomly done. Incision length was grouped into 1.5, 2 and 2.5 mm. CHIP was graded as nil, mild, moderate or severe: nil - no visible CHIP, mild-CHIP involving pillars of the incision, moderate - CHIP involving pillars and lateral extension, severe - extension of CHIP in front into the clear cornea. Moderate and severe categories were combined as 'significant' CHIP. Statistical analysis was done by logistic regression. RESULTS The incidence of significant CHIP was 17.9 % (43 eyes out of 240). Five out of 80 eyes (6.25%) single plane, 8 out of 80 (10%) two plane and 30 out of 80 (37.5%) three- plane incisions developed significant CHIP (p = 0.005). Fifteen out of 120 (12.5%) with and 28 out of 120 (23.3%) without injection of viscoelastic developed significant CHIP (p = 0.044). Eighteen out of 43 (42.8%) and 25 out of 43(58.1%) with incision lengths 2 and 2.5 mm developed significant CHIP respectively (p<0.001). CONCLUSIONS The incidence of significant CHIP was 17.9 %. Three-plane incisions, not injecting viscoelastic prior to retraction of instruments and incision length 2 mm or more are risk factors for significant CHIP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Irrigation port hydration in phacoemulsification surgery

Background In most cases, hydration is performed by water injection into the stromal tissue with a needle. The technique is simple, however it is sometimes troublesome. Purpose We describe a simple technique for hydrating the corneal stroma in cataract surgery using an irrigation port. Patients and methods The technique began by pushing the irrigation port against the corneal stroma for a f...

متن کامل

Phacoemulsification surgery by a nationally-trained cataract surgeon of Nepal.

INTRODUCTION A one month phacoemulsification training course had been implemented by the Nepal Netra Jyoti Sangh (NNJS) in collaboration with Association for Ophthalmic Cooperation to Asia, Japan (AOCA). OBJECTIVE To evaluate the visual outcomes of phacoemulsification surgery by a nationally trained surgeon in Nepal. MATERIALS AND METHODS A retrospective study of patients that underwent pha...

متن کامل

The effect of stromal hydration on surgical outcomes for cataract patients who received a hydrogel ocular bandage

PURPOSE The purpose of this study was to examine the effect of stromal hydration on surgical outcomes for patients who received the new hydrogel ocular bandage (ReSure™ Adherent Ocular Bandage, Ocular Therapeutix, Inc, Bedford, MA, USA) following routine cataract surgery. METHODS This post-hoc, single-masked study was conducted with 310 patients who were scheduled to undergo unilateral clear ...

متن کامل

Change in refractive status of the patients undergoing phacoemulsification surgery.

This study was carried out with the objective of finding refractive status of patients undergoing phacoemulsification surgery for cataract extraction. Success of cataract surgery can be quantified with the improvement in visual acuity with least amount of refractive error. Prospective study of 44 patients was done pre operatively and with subsequent follow up in the first, third and eighth week...

متن کامل

Intraoperative fracture of phacoemulsification sleeve

BACKGROUND We describe a case of intraoperative fracture of phacoemulsification sleeve during phacoemulsification surgery. CASE PRESENTATION Phacoemulsification surgery was performed in the left eye of a 58-year-old lady with grade II nuclear sclerosis & grade I cortical cataract. Towards the end of quadrant removal, there was anterior chamber instability with impaired followability of nuclea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indian journal of ophthalmology

دوره 53 4  شماره 

صفحات  -

تاریخ انتشار 2005