Saturated double-angle method for rapid B1+ mapping.

نویسندگان

  • Charles H Cunningham
  • John M Pauly
  • Krishna S Nayak
چکیده

For in vivo magnetic resonance imaging at high field (> or =3 T) it is essential to consider the homogeneity of the active B(1) field (B(1)+), particularly if surface coils are used for RF transmission. A new method is presented for highly rapid B(1)+ magnitude mapping. It combines the double angle method with a B(1)-insensitive magnetization-reset sequence such that the choice of repetition time (TR) is independent of T(1) and with a multislice segmented (spiral) acquisition to achieve volumetric coverage with adequate spatial resolution in a few seconds. Phantom experiments confirmed the accuracy of this technique even when TR << T(1), with the side effect being lowered SNR. The speed of this method enabled B(1)+ mapping in the chest and abdomen within a single breath-hold. In human cardiac imaging, the method enabled whole-heart coverage within a single 16-s breath-hold. Results from phantoms and healthy volunteers at 1.5 T and 3 T are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Motion-robust cardiac B1+ mapping at 3T using interleaved bloch-siegert shifts.

PURPOSE To develop and evaluate a robust motion-insensitive Bloch-Siegert shift based B1+ mapping method in the heart. METHODS Cardiac Bloch-Siegert B1+ mapping was performed with interleaved positive and negative off-resonance shifts and diastolic spoiled gradient echo imaging in 12 heartbeats. Numerical simulations were performed to study the impact of respiratory motion. The method was com...

متن کامل

Signal to Noise Ratio Analysis of Bloch-Siegert B1 Mapping

Introduction: B1 mapping is important in a variety of new MR applications, including the design of RF pulses in parallel transmit systems and flip angle calibration for T1 mapping. The Bloch-Siegert (BS) B1 mapping method has been recently introduced as a fast, accurate and robust technique for B1 mapping [1]. In order to compare the quality of B1 maps acquired with the BS method to other metho...

متن کامل

Measurement and characterization of RF nonuniformity over the heart at 3T using body coil transmission.

PURPOSE To measure and characterize variations in the transmitted radio frequency (RF) (B1+) field in cardiac magnetic resonance imaging (MRI) at 3 Tesla. Knowledge of the B1+ field is necessary for the calibration of pulse sequences, image-based quantitation, and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) optimization. MATERIALS AND METHODS A variation of the saturated dou...

متن کامل

No Inversion Double Angle Look-Locker (niDALL) for Flip Angle Mapping

Introduction: Transmit B1 inhomogeneity is a major problem at higher field strengths. The RF wavelength decreases with increasing field strength and at 3T and above begins to approach the same scale as the human body. This leads to destructive interference and non-uniform excitation of tissue. Methods exist for correcting this non-uniformity, but mapping the B1 field is a prerequisite. One meth...

متن کامل

Interactive B1+ Non-uniformity Compensation using TIP- COMP

Introduction: In cardiac imaging, it is essential to consider the homogeneity of the active B1 field (B1+) [1]. We present a realtime implementation of Transmit In-Plane Compensation (TIP-COMP) RF pulse [2], which can compensate different B1+ variations. Methods: Experiments were performed on a GE Signa EXCITE 3.0T system using a custom real-time imaging system [3]. To validate the accuracy of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 55 6  شماره 

صفحات  -

تاریخ انتشار 2006