Automation of the cytokinesis-block micronucleus cytome assay by laser scanning cytometry and its potential application in radiation biodosimetry.

نویسندگان

  • Maxime François
  • Kevin Hochstenbach
  • Wayne Leifert
  • Michael Felix Fenech
چکیده

Here we describe the adaptation of laser scanning cytometry (LSC) to measure micronuclei (MN) automatically in lymphocytes. MN frequencies were determined in irradiated human lymphocytes using the cytokinesis-block technique, and the results from LSC were compared with visual scoring results obtained from slides of cells stained using Fast Green and 4',6-diamidino-2-phenylindole (DAPI). This fluorescent approach allowed clear identification of binucleated cells and detection of MN. The dose responses measured visually and by LSC showed similar trends and correlated positively (r = 0.9689; P < 0.0001). High-content analysis was developed to further automatically score MN within mono-, tri- and tetra-nucleated cells and to determine the nuclear division index and nuclear circularity values. The high-throughput nature of LSC can provide unique advantages in future DNA damage diagnostics in experimental and epidemiological studies. Importantly, it allows for co-detection of other biomarkers of interest within a single lymphocyte, and further development of this capability is anticipated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A lifetime passion for micronucleus cytome assays--reflections from Down Under.

A brief account of an improbable career in the field of genetic toxicology is given, extending from my early years in Malta through a life-changing decision to study in Australia (Down Under). I describe the circumstances that led to the discovery of the cytokinesis-block micronucleus (CBMN) assay and its evolution into a cytome assay of chromosome breakage and loss (micronuclei), asymmetrical ...

متن کامل

The Application of Imaging Flow Cytometry to High-Throughput Biodosimetry

Biodosimetry methods, including the dicentric chromosome assay, the cytokinesis-block micronucleus assay and the γH2AX marker of DNA damage are used to determine the dose of ionizing radiation. These techniques are particularly useful when physical dosimetry is absent or questioned. While these assays can be very sensitive and specific, the standard methods need to be adapted to increase sample...

متن کامل

Cytokinesis blocked micronucleus (CB-MN) assay for biodosimetry of high dose accidental exposure

Background: Most of the cytogenetic dosimetry, except Premature Chromosome Condensation assay, saturates at 6 Gy. Present studies are aimed to assess feasibility of simple CB-MN assay for prescreening of high dose accidental exposures. Materials and Methods: Human peripheral blood lymphocytes from two donors were gamma irradiated to different doses ranging from 0-15Gy, cultured for 72 h. Cytoch...

متن کامل

Different aspects of cytochalasin B Blocked micronucleus cytome (CBMN cyt) assay as a comprehensive measurement tool for radiobiological studies, biological dosimetry and genome instability

It is now universally accepted that DNA is the main target for damages caused by physical and chemical genotoxicants. Although there are different methods to measure directly the induced DNA damages but due to fast repair processes in cellular environment, most of the damages would be repaired even before sampling, therefore processed DNA damages, i.e. damages left unrepaired after acting repai...

متن کامل

Development of a High-Throughput and Miniaturized Cytokinesis-Block Micronucleus Assay for Use as a Biological Dosimetry Population Triage Tool.

Biodosimetry is an essential tool for providing timely assessments of radiation exposure. For a large mass-casualty event involving exposure to ionizing radiation, it is of utmost importance to rapidly provide dose information for medical treatment. The well-established cytokinesis-block micronucleus (CBMN) assay is a validated method for biodosimetry. However, the need for an accelerated sampl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioTechniques

دوره 57 6  شماره 

صفحات  -

تاریخ انتشار 2014