BACKGROUND AND PURPOSE Silent ischemic embolic lesions are common after transcatheter aortic valve implantation (TAVI). The use of embolic protection devices (EPD) may reduce the occurrence of these embolic lesions. Thus, a quantitative overview and credibility assessment of the literature was necessary to draw a robust message about EPD. Therefore, the aim of this meta-analysis was to study whether the use of EPD reduces silent ischemic and clinically evident cerebrovascular events associated with TAVI. METHODS We conducted a comprehensive search to identify studies that evaluated patients undergoing TAVI with or without EPD. Random-effects meta-analyses were performed to estimate the effect of EPD compared with no-EPD during TAVI using aggregate data. RESULTS Sixteen studies involving 1170 patients (865/305 with/without EPD) fulfilled the inclusion criteria. The EPD delivery success rate was reported in all studies and was achieved in 94.5% of patients. Meta-analyses evaluating EPD versus without EPD strategies could not confirm or exclude any differences in terms of clinically evident stroke (relative risk, 0.70; 95% confidence interval [CI], 0.38-1.29; P=0.26) or 30-day mortality (relative risk, 0.58; 95% CI, 0.20-1.64; P=0.30). There were no significant differences in new-single, multiple, or total number of lesions. The use of EPD was associated with a significantly smaller ischemic volume per lesion (standardized mean difference, -0.52; 95% CI, -0.85 to -0.20; P=0.002) and smaller total volume of lesions (standardized mean difference, -0.23; 95% CI, -0.42 to -0.03; P=0.02). Subgroup analysis by type of valve showed an overall trend toward significant reduction in new lesions per patient using EPD (standardized mean difference, -0.41; 95% CI, -0.82 to 0.00; P=0.05), driven by self-expanding devices. CONCLUSIONS The use of EPD during TAVI may be associated with smaller volume of silent ischemic lesions and smaller total volume of silent ischemic lesions. However, EPD may not reduce the number of new-single, multiple, or total number of lesions. There was only very low quality of evidence showing no significant differences between patients undergoing TAVI with or without EPD with respect to clinically evident stroke and mortality.
منابع مشابه
First-in-man use of a novel embolic protection device for patients undergoing transcatheter aortic valve implantation.
AIMS We describe the first-in-human experience with a novel cerebral embolic protection device used during transcatheter aortic valve implantation (TAVI). One current challenge of TAVI is the reduction of procedural stroke. Procedural mobilisation of debris is a known source of cerebral embolisation. Mechanical protection by transient filtration of cerebral blood flow might reduce the embolic b...
متن کاملRetinal embolic events: frequency and impact following transcatheter aortic valve implantation (TAVI) for aortic stenosis
Objectives Transcatheter aortic valve implantation (TAVI) is an established treatment for patients with severe symptomatic aortic stenosis. It has a cerebrovascular accident rate of about 5% but the effect on retinal embolic events has not been previously reported. This study investigated the occurrence of retinal emboli following TAVI. Methods and analysis In this prospective observational s...
متن کاملHistological Findings and Predictors of Cerebral Debris From Transcatheter Aortic Valve Replacement: The ALSTER Experience
BACKGROUND Histopathological analyses of debris captured by a cerebral protection system during transcatheter aortic valve replacement have been reported, but the origin of the captured debris was not determined and risk factors were not defined. METHODS AND RESULTS Embolic debris was analyzed from 322 filters used in a dual-cerebral-filter protection system implemented during transcatheter a...
متن کاملEmbolic Protection Devices in Transcatheter Aortic Valve Replacement
Abstract—The initially reported periprocedural neurological events rates associated with transcatheter aortic valve replacement raised concerns that ultimately led to the development and to the clinical research of novel embolic protection devices. Although the reduction of clinical stroke is a desired goal, the current research design of embolic protection devices focuses on surrogate markers ...
متن کاملLetter by Fanning et al regarding article, "Histopathology of embolic debris captured during transcatheter aortic valve replacement".
We congratulate Van Mieghem and colleagues for the significant contribution they have made to the understanding of the embolic phenomena associated with transcatheter aortic valve implantation through their article, " Histopathology of Embolic Debris Captured During Transcatheter Aortic Valve Replacement. " 1 Somewhat surprising is the high occurrence of thrombotic material, which was identifie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 48 5 شماره
صفحات -
تاریخ انتشار 2017