Estimating and Controlling Atomic Chlorine Concentration via Actinometry
نویسندگان
چکیده
Actinometry has been used as the basis of a successful sensor for controlling uorine concentration in uoro-carbon plasmas commonly employed in etching. An analogous sensor would be useful for chlorine plasmas as well. One problem with actinometry in Cl2 plasmas is that excitation can occur by electron impact dissociation and by dissociative attachment, leading to potential ambiguity between the intensity of observed chlorine emission in a plasma and the actual concentration of chlorine. On the basis of a simple model, this paper analyzes the consequences of the dissociative excitation pathway on the accuracy of the estimation and control of chlorine concentration via actinometry. When the contribution of the dissociative excitation pathway is known, it is shown that asymptotic observer theory can be used to improve the accuracy of the estimation of chlorine concentration.
منابع مشابه
Controlling of Absorption and Dispersion Spectrum via Electromagnetically Induced Transparency
In this paper we examine the absorption and dispersion properties of a weak probe field via Electromagnetically Induced Transparency (EIT) in a four-level system. It is shown that under certain condition, using this model, the absorption cancellation is appeared and the medium becomes transparent to the weak probe field. It will be shown that the controlling of absorption and dispersion spectru...
متن کاملEvaluation of basis sets and theoretical methods for estimating rate constants of mercury oxidation reactions involving chlorine
The occurrence of elemental mercury in flue gases from coal combustion is a problem of current environmental concern. Oxidized mercury species can be effectively removed from the flue gases by chemical scrubbers. However, the detailed mechanism by which oxidation occurs remains unclear. Theoretical rate constants are calculated for mercury oxidation by atomic chlorine. The potential energy surf...
متن کاملDetermination chlorine of groundwater with electrical conductivity by Geostatistical methods (Case study of drinking water wells Mashhad)
Information on chlorine concentration in groundwater for drinking and agriculture is important. If theconcentration of this element is in too much water can cause problems for humans and is toxic toplants. Measurement of chloride in groundwater is extensive, costly and time consuming. Find easyand inexpensive method has a special importance. the Statistical methods are based on spatialvariables...
متن کاملAnalysis of the etching of silicon in an inductively coupled chlorine plasma using laser thermal desorption
The etching of silicon by a chlorine inductively coupled plasma ~ICP! was studied using laser desorption laser-induced fluorescence ~LD-LIF! analysis to determine the surface coverage of chlorine during steady-state etching. Laser interferometry was used to measure etch rates, and optical emission actinometry and Langmuir probe analysis were used to characterize the plasma. The ICP operated in ...
متن کاملInteraction of wide-band-gap single crystals with 248-nm excimer laser irradiation. IX. Photoinduced atomic desorption from cleaved NaCl„100... surfaces
Neutral atomic sodium and chlorine emissions from cleaved, single-crystal NaCl 100 surfaces due to pulsed, 248-nm excimer laser irradiation have been characterized by time-resolved, quadrupole mass spectroscopy. At laser fluences below the threshold for optical breakdown, the resulting time-of-flight signals are consistent with particles emitted in thermal equilibrium with a laser-heated surfac...
متن کامل