Mitral valve replacement with and without chordal preservation in patients with chronic mitral regurgitation. Mechanisms for differences in postoperative ejection performance.
نویسندگان
چکیده
BACKGROUND Standard mitral valve replacement (MVR) in patients with chronic mitral regurgitation consistently results in a decrease in postoperative left ventricular (LV) ejection performance. This fall in ejection performance has been attributed, at least in part, to unfavorable loading conditions imposed by the elimination of the low-impedance pathway for LV emptying into the left atrium. In contrast to standard MVR in which the chordae tendineae are severed, however, MVR with chordal preservation (MVR-CP) does not usually decrease LV ejection performance despite similar removal of the low-impedance pathway. The purpose of the present study was to define the mechanisms responsible for this discordance in postoperative ejection performance between MVR with and without chordal preservation. METHODS AND RESULTS Echocardiography and sphygmomanometer blood pressures were obtained in 15 patients with pure chronic mitral regurgitation before and 7-10 days after mitral valve surgery. These measurements were used to calculate ventricular volume, wall stress, and ejection fraction. Seven patients underwent MVR with chordal transection (MVR-CT), and eight patients underwent MVR-CP. MVR-CT resulted in no postoperative change in LV end-diastolic volume, a significant increase in LV end-systolic volume, a significant increase in end-systolic stress, from 89 +/- 9 to 111 +/- 12 g/cm2 (p < 0.05), and a significant decrease in ejection fraction, from 0.60 +/- 0.02 to 36 +/- 0.02 (p < 0.05). In contrast, patients who underwent MVR-CP had a significant decrease in LV end-diastolic and end-systolic volumes. End-systolic wall stress actually fell from 95 +/- 6 to 66 +/- 6 g/cm2 (p < 0.05), and ejection fraction was unchanged (0.63 +/- 0.01 before and 0.61 +/- 0.02 after mitral valve surgery) instead of reduced. CONCLUSIONS MVR-CT resulted in a decrease in ejection performance caused in part by an increase in end-systolic stress, which in turn increased end-systolic volume. Conversely, MVR-CP resulted in a smaller LV size, allowing a reduced end-systolic stress and preservation of ejection performance despite closure of the low-impedance left atrial ejection pathway.
منابع مشابه
High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient
Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...
متن کاملRandomized trial of partial versus complete chordal preservation methods of mitral valve replacement: A preliminary report.
BACKGROUND The merits of retaining the subvalvular apparatus during mitral valve replacement for chronic mitral regurgitation have been demonstrated in numerous clinical and laboratory investigations. In this preliminary report, we analyzed the early effects of complete versus partial chordal preservation on left ventricular mechanics. METHODS AND RESULTS Fifty patients undergoing isolated su...
متن کامل132 Mitral Valve Replacement Versus Mitral Valve Repair
Background Standard mitral valve replacement (MVR) in patients with chronic mitral regurgitation results in consistent reductions in resting postoperative ejection fraction. This has been attributed to removal of the low-impedance ejection pathway into the left atrium or to disruption of the chordal apparatus. Mitral valve repair (MVP) does not reduce ejection fraction at rest. However, whether...
متن کاملRight sided heart evaluation after successful mitral valve replacement.
Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...
متن کاملComparative assessment of chordal preservation versus chordal resection in mitral valve replacement for mitral stenosis (long-term follow-up: 8 years).
Carrying out a mitral valve replacement (MVR) while preserving all chordae tendineae in patients with mitral regurgitation has been proven beneficial to the left ventricular performance. To evaluate the effectiveness of this technique in patients with mitral stenosis, a comparison of the echocardiographic data between patients who were operated on using this technique (Group Preservation = Grou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 86 6 شماره
صفحات -