چکیده

BACKGROUND Clinical tests to assess peripheral nerve disorders can be classified into two categories: tests for afferent/efferent nerve function such as nerve conduction (bedside neurological examination) and tests for increased mechanosensitivity (e.g. upper limb neurodynamic tests (ULNTs) and nerve palpation). Reliability reports of nerve palpation and the interpretation of neurodynamic tests are scarce. This study therefore investigated the intertester reliability of nerve palpation and ULNTs. ULNTs were interpreted based on symptom reproduction and structural differentiation. To put the reliability of these tests in perspective, a comparison with the reliability of clinical tests for nerve function was made. METHODS Two experienced clinicians examined 31 patients with unilateral arm and/or neck pain. The examination included clinical tests for nerve function (sensory testing, reflexes and manual muscle testing (MMT)) and mechanosensitivity (ULNTs and palpation of the median, radial and ulnar nerve). Kappa statistics were calculated to evaluate intertester reliability. A meta-analysis determined an overall kappa for the domains with multiple kappa values (MMT, ULNT, palpation). We then compared the difference in reliability between the tests of mechanosensitivity and nerve function using a one-sample t-test. RESULTS We observed moderate to substantial reliability for the tests for afferent/efferent nerve function (sensory testing: kappa = 0.53; MMT: kappa = 0.68; no kappa was calculated for reflexes due to a lack of variation). Tests to investigate mechanosensitivity demonstrated moderate reliability (ULNT: kappa = 0.45; palpation: kappa = 0.59). When compared statistically, there was no difference in reliability for tests for nerve function and mechanosensitivity (p = 0.06). CONCLUSION This study demonstrates that clinical tests which evaluate increased nerve mechanosensitivity and afferent/efferent nerve function have comparable moderate to substantial reliability. To further investigate the clinometric properties of these tests, more studies are needed to evaluate their validity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability of Upper Limb Neurodynamic Tests: Median, Radial and Ulnar Nerves

Objective: in the evaluation of peripheral nerves, upper limb neurodynamic tests are used to assess the mechanical sensitivity of the nerve. However, very little is known about the reliability of upper limb neurodynamic tests, especially for the radial and ulnar nerves. The aim of this study was to evaluate the reliability of neurodynamic tests of the upper extremities including median, radial ...

متن کامل

Side-to-side range of movement variability in variants of the median and radial neurodynamic test sequences in asymptomatic people.

Side-to-side discrepancy in range of motion (ROM) during upper limb neurodynamic testing is used in part to identify abnormal peripheral nerve mechanosensitivity and is one of three factors to consider in determining a positive test. Large side-to-side variability is reported for some variants of the upper limb neurodynamic test sequences, however discrepancies for other test variants are unkno...

متن کامل

Upper Limb Neural Tissue Extensibility in Apparently Asymptomatic Professional Computer users

Introduction: Assessment of peripheral nerve disorders can be classified into clinical tests such nerve conduction test, performed to examine nerve functions and Neural Tissue Tension Tests designed to find out increased mechanosensitivity of the nerve being tested. Upper Limb Neural Tissue Tension Tests (ULTT) is a good tool for assessment of early affection of the neural tissue. Purpose of St...

متن کامل

Diagnostic accuracy of the neurological upper limb examination I: Inter-rater reproducibility of selected findings and patterns

BACKGROUND We have previously assessed the reproducibility of manual testing of the strength in 14 individual upper limb muscles in patients with or without upper limb complaints. This investigation aimed at additionally studying sensory disturbances, the mechanosensitivity of nerve trunks, and the occurrence of physical findings in patterns which may potentially reflect a peripheral neuropathy...

متن کامل

Peripheral Neuro Electrodiagnostic Abnormalities in Patients with Multiple Sclerosis: A Cross Sectional Study

Background: Multiple sclerosis (MS) is known to affect essentially the central nervous system; however, peripheral nerve involvement, as an additional cause of disability, has been recently noticed. Objectives: This study was aimed to perform detailed electrodiagnostic assessments in MS patients to evaluate peripheral nervous system involvement. Materials and Methods: A total of eighty MS...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC Musculoskeletal Disorders

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2009