Validity of lamellar body count as a fetal lung maturity assessment in twin pregnancy.

نویسندگان

  • Hiroyuki Tsuda
  • Tomomi Kotani
  • Seiji Sumigama
  • Ichiro Kawabata
  • Yuichiro Takahashi
  • Shigenori Iwagaki
  • Kaori Kigoshi
  • Fumitaka Kikkawa
چکیده

Fetal lung maturity assessment in twin pregnancy has been discussed, but is still controversial. The purpose of this study is to predict the occurrence of respiratory distress syndrome (RDS) using lamellar body count (LBC) and analyze the validity of LBC for fetal lung maturity assessment in twin pregnancy. Three-hundred two amniotic fluid samples were obtained at cesarean section from 29 to 38 weeks of gestation. Samples were analyzed immediately with no centrifugation and the number of lamellar bodies was counted using a platelet channel on the Sysmex SF-3000. There were 18 neonates (6.0%) suffering from RDS. An LBC cut-off value of 2.95×10⁴/μL resulted in 91.5% sensitivity and 83.3% specificity for predicting RDS. This cut-off value for predicting RDS was the same as that in singleton pregnancy. Moreover, the median LBC value in RDS cases was significantly lower than in non-RDS cases (1.50±1.1×10⁴/μL vs. 10.6±7.5×10⁴/μL; p<.001). This is the first report on the validity of LBC in twin pregnancy and also the largest study on fetal lung maturity assessment in twin pregnancy. An LBC value of >2.95×10⁴/μL means reassuring findings for RDS even in twin pregnancy. We believe the data in this study provide valuable, new information for the management of twin pregnancies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The ways of amniotic fluid sampling and its influence on lamellar body count.

Even though artificial surfactant is now available, respiratory distress syndrome still remains a serious problem in neonatology. Prenatal analysis of the amniotic fluid can provide data giving insight into the fetal lung maturity, which enables planning of the further outcome of high-risk pregnancies. Surfactant prevents atelectasis by forming a layer rich in phospholipids between the air and ...

متن کامل

Sedimentation of lung-derived phospholipid during low-speed centrifugation of amniotic fluid.

In most methods proposed for the assessment of fetal lung maturity, amniotic fluid is subjected to a preliminary low-speed centrifugation in an attempt to separate whole cells and cell debris from lung-derived surfactant phospholipid (lamellar body phospholipid). However, because lamellar body phospholipid is present in amniotic fluid in a membranous or particulate form, it is also partly sedim...

متن کامل

Lamellar body count as a diagnostic test in predicting neonatal respiratory distress syndrome

AIM To determine the lamellar body count (LBC) cutoff value for fetal lung maturity and to evaluate the clinical usefulness of LBC in predicting the severity of neonatal respiratory distress syndrome (RDS). METHODS A prospective study was conducted from 2002 until 2010. LBC was estimated in uncentrifugated amniotic fluid samples using Cell-Dyn 1800 analyzer. Amniotic fluid samples were obtain...

متن کامل

Predicting lung maturity in preterm rupture of membranes via lamellar bodies count from a vaginal pool: a cohort study

BACKGROUND Amniocentesis is the accepted mode of attaining amniotic fluid to perform tests for fetal lung maturity. The purpose of this study was to validate a non-invasive fetal lung maturity test by counting lamellar bodies from a vaginal pool among women with preterm premature rupture of membranes. METHODS In a prospective study, amniotic fluid specimens were collected from a vaginal pool ...

متن کامل

Lamellar body phospholipid content of amniotic fluid and L/S ratio compared in assessing fetal lung maturity.

A micro-method has been devised for isolating a lung-derived membranous fraction from human amniotic fluid. The phospholipid content of this fraction, known as lamellar body phospholipid, provides an indication of fetal lung maturity (Ann. Clin. Biochem 16: 191, 1979). This method has now been applied to 479 samples of amniotic fluid from 330 pregnancies. The lecithin/sphingomyelin ratio has al...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Twin research and human genetics : the official journal of the International Society for Twin Studies

دوره 15 4  شماره 

صفحات  -

تاریخ انتشار 2012