Systolic mechanical properties of the left ventricle. Effects of volume and contractile state.

نویسندگان

  • W C Hunter
  • J S Janicki
  • K T Weber
  • A Noordergraaf
چکیده

To characterize the mechanical properties of the contracting left ventricle, we studied the changes in left ventricular systolic pressure following step-like perturbations (+/- 3 ml) in ventricular volume, using an isovolumically beating, isolated canine heart preparation. Three mechanical properties (elasticity, resistance, and a deactivation effect) were identified. The elastic property differs from the traditional parallel and series elastic elements; it is a time-varying elasticity that includes active and passive effects of volume changes. Furthermore, it could not be represented by a simple time-varying elasticity, but required a second factor to express the dependence of end-systolic elasticity on the timing of the volume step. This effect was represented by a "volume influence factor," which may arise from length-dependent activation. The resistive property appeared to be related to force-velocity behavior of the myocardium. Each mechanical property reacted characteristically to steady state changes in ventricular filling volume or contractile state produced by dobutamine (2-13 micrograms/min). Our findings indicate that elasticity was the property most sensitive to changes in contractile state; these changes increased peak isovolumetric pressure 54% on average, and raised elastic stiffness 40% above control (which was 5.1 mm Hg/ml). Changes in ventricular filling volume only prolonged, but did not alter, the level of elastic stiffness attained at peak pressure. These results support the view that elasticity--or the end-systolic pressure-volume relationship--serves in a given heart to quantify contractility. The "volume influence factor" was not affected by either filling volume or contractile state. Resistance increased in direct proportion with ventricular pressure, but this linear relation was not altered greatly by changes in contractile state or in ventricular filling volume. At 100 mm Hg, ventricular resistance averaged 0.11 mm Hg/ml per sec. Finally, deactivation was greater the later in systole a volume step was imposed, and this pattern was independent of changes in ventricular filling volume and in contractile state.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of heart rate on ventricular performance, myocardial contractile state and coronary circulation.

IKEDA, S. Effects of Heart Rate on Ventricular Performance, Myocardial Contractile State and Coronary Circulation. Tohoku J. exp. Med., 1974, 112 (1), 89-100Effects of heart rate on ventricular performance, myocardial contractile state and coronary circulation were studied under constant cardiac output in right heart by-passed anesthetized dogs. Myocardial contractile state (Vmax) was elevated ...

متن کامل

Contractile state of the left ventricle in man as evaluated from end-systolic pressure-volume relations.

End-systolic pressure (PES), volume (VES), wall tension (TES) and circumference (CES) of the human left ventricle were studied at cardiac catheterization in 24 subjects with varying degrees of left ventricular dysfunction. Acute alterations in systolic load consistently resulted in changes in VES and CES, with a smaller volume and circumference characterizing the lower systolic load in each sub...

متن کامل

Effect of positive inotropic agents on the relation between oxygen consumption and systolic pressure volume area in canine left ventricle.

We analyzed the effect of positive inotropic agents on the relation between left ventricular oxygen consumption and the systolic pressure-volume area. Pressure-volume area is a measure of total mechanical energy for ventricular contraction, and is a specific area in the ventricular pressure-volume diagram circumscribed by the end-systolic and end-diastolic pressure-volume relation curves and th...

متن کامل

End-systolic pressure determines stroke volume from fixed end-diastolic volume in the isolated canine left ventricle under a constant contractile state.

We studied the effect of systolic pressure and volume changes on the end-systolic pressure at a fixed end-systolic volume in the left ventricle of excised, cross-circulated canine hearts. Instantaneous ventricular volume was controlled and both end-diastolic and end-systolic volumes were clamped, as preprogrammed by a volume servo pump system. Ventricular ejection was completed at the end of na...

متن کامل

Force-time integral decreases with ejection despite constant oxygen consumption and pressure-volume area in dog left ventricle.

We have shown that systolic pressure-volume area (PVA), which is equivalent to the total mechanical energy generated by ventricular contraction, correlates linearly with myocardial oxygen consumption, VO2, in canine left ventricle. Systolic force-time integral, FTI, also correlates with VO2. In this study, stroke volume was increased from 0 (isovolumic) in isolated cross-circulated canine left ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 52 3  شماره 

صفحات  -

تاریخ انتشار 1983