Refixation of Osteochondral Fractures by an Ultrasound-Activated Pin System – An Ovine In Vivo Examination Using CT and Scanning Electron Microscope
نویسندگان
چکیده
BACKGROUND Osteochondral injuries, if not treated appropriately, often lead to severe osteoarthritis of the affected joint. Without refixation of the osteochondral fragment, human cartilage only repairs these defects imperfectly. All existing refixation systems for chondral defects have disadvantages, for instance bad MRI quality in the postoperative follow-up or low anchoring forces. To address the problem of reduced stability in resorbable implants, ultrasound-activated pins were developed. By ultrasound-activated melting of the tip of these implants a higher anchoring is assumed. Aim of the study was to investigate, if ultrasound-activated pins can provide a secure refixation of osteochondral fractures comparing to conventional screw and conventional, resorbable pin osteosynthesis. CT scans and scanning electron microscopy should proovegood refixation results with no further tissue damage by the melting of the ultrasound-activated pins in comparison to conventional osteosynthesis. METHODS Femoral osteochondral fragments in sheep were refixated with ultrasound-activated pins (SonicPin™), Ethipins(®) and screws (Asnis™). The quality of the refixated fragments was examined after three month of full weight bearing by CT scans and scanning electron microscopy of the cartilage surface. RESULTS The CT examination found almost no statistically significant difference in the quality of refixation between the three different implants used. Concerning the CT morphology, ultrasound-activated pins demonstrated at least the same quality in refixation of osteochondral fragments as conventional resorbable pins or screws. The scanning electron microscopy showed no major surface damage by the three implants, especially any postulated cartilage damage induced by the heat of the ultrasound-activated pin. The screws protruded above the cartilage surface, which may affect the opposingtibial surface. CONCLUSION Using CT scans and scanning electron microscopy, the SonicPin™, the Ethipin(®) and screws were at least equivalent in refixation quality of osteochondral fragments.
منابع مشابه
Refixation of osteochondral fractures by ultrasound-activated, resorbable pins
OBJECTIVES Osteochondral injuries, if not treated adequately, often lead to severe osteoarthritis. Possible treatment options include refixation of the fragment or replacement therapies such as Pridie drilling, microfracture or osteochondral grafts, all of which have certain disadvantages. Only refixation of the fragment can produce a smooth and resilient joint surface. The aim of this study wa...
متن کاملEffects of ultrasound on properties of ni-metal organic framework nanostructures
Objective(s): According to the unique properties of magnetic nanoparticles, Nickel Metal-Organic Frameworks (MOF) was synthesized successfully by ultrasound irradiation. Metal-organic frameworks (MOFs) are organic–inorganic hybrid extended networks that are constructed via covalent linkages between metal ions/metal clusters and organic ligands called a linker. Materials and Methods: The nanopar...
متن کاملLong-Term Clinical and MRI Results after Refixation of osteochondral Fractures with resorbable Implants
AIM Refixation of osteochondral fractures with resorbable implants is a common surgical treatment. There are almost no studies that prove good clinical outcomes. Hence, the aim of the study was to evaluate the mid-term results after refixation of osteochondral fractures. METHODS The results of 12 patients were recorded 6.5 (±1) years after refixation of osteochondral fractures measuring 3.4 c...
متن کاملCreep Life Assessment of Primary Reformer HP40-NB Modified Steel Tube of an Ammonia Plant
Assessment of creep damage and residual creep life of a cast HP 40 Nb Mod. Reformer tube was performed, wherein the experimental Larson–Miller diagram and area fraction of creep voids were adopted. The state of damage of the tube in service was metallographically analyzed by using light and electron microscopy. Samples from the serviced reformer furnace tube were cut and prepared for void exami...
متن کاملFloating microspheres encapsulating carvedilol for the effective management of hypertension
Carvedilol (CVD) is an antihypertensive agent with a short half-life, pH-dependent solubility, and narrow absorption window. The purpose of this research was to prepare a floating-drug delivery-system of carvedilol to increase its half-life. The present study investigates the preparation of carvedilol-floating microspheres, evaluates the floating-drug delivery-system (FDDS) (by scanning electro...
متن کامل