Prediction error and accuracy of intraocular lens power calculation in pediatric patient comparing SRK II and Pediatric IOL Calculator

نویسندگان

  • Azlyn-Azwa Jasman
  • Bakiah Shaharuddin
  • Raja-Azmi M Noor
  • Shatriah Ismail
  • Zulkifli A Ghani
  • Zunaina Embong
چکیده

BACKGROUND Despite growing number of intraocular lens power calculation formulas, there is no evidence that these formulas have good predictive accuracy in pediatric, whose eyes are still undergoing rapid growth and refractive changes. This study is intended to compare the prediction error and the accuracy of predictability of intraocular lens power calculation in pediatric patients at 3 month post cataract surgery with primary implantation of an intraocular lens using SRK II versus Pediatric IOL Calculator for pediatric intraocular lens calculation. Pediatric IOL Calculator is a modification of SRK II using Holladay algorithm. This program attempts to predict the refraction of a pseudophakic child as he grows, using a Holladay algorithm model. This model is based on refraction measurements of pediatric aphakic eyes. Pediatric IOL Calculator uses computer software for intraocular lens calculation. METHODS This comparative study consists of 31 eyes (24 patients) that successfully underwent cataract surgery and intraocular lens implantations. All patients were 12 years old and below (range: 4 months to 12 years old). Patients were randomized into 2 groups; SRK II group and Pediatric IOL Calculator group using envelope technique sampling procedure. Intraocular lens power calculations were made using either SRK II or Pediatric IOL Calculator for pediatric intraocular lens calculation based on the printed technique selected for every patient. Thirteen patients were assigned for SRK II group and another 11 patients for Pediatric IOL Calculator group. For SRK II group, the predicted postoperative refraction is based on the patient's axial length and is aimed for emmetropic at the time of surgery. However for Pediatric IOL Calculator group, the predicted postoperative refraction is aimed for emmetropic spherical equivalent at age 2 years old. The postoperative refractive outcome was taken as the spherical equivalent of the refraction at 3 month postoperative follow-up. The data were analysed to compare the mean prediction error and the accuracy of predictability of intraocular lens power calculation between SRK II and Pediatric IOL Calculator. RESULTS There were 16 eyes in SRK II group and 15 eyes in Pediatric IOL Calculator group. The mean prediction error in the SRK II group was 1.03 D (SD, 0.69 D) while in Pediatric IOL Calculator group was 1.14 D (SD, 1.19 D). The SRK II group showed lower prediction error of 0.11 D compared to Pediatric IOL Calculator group, but this was not statistically significant (p = 0.74). There were 3 eyes (18.75%) in SRK II group achieved accurate predictability where the refraction postoperatively was within ± 0.5 D from predicted refraction compared to 7 eyes (46.67%) in the Pediatric IOL Calculator group. However the difference of the accuracy of predictability of postoperative refraction between the two formulas was also not statistically significant (p = 0.097). CONCLUSIONS The prediction error and the accuracy of predictability of postoperative refraction in pediatric cataract surgery are comparable between SRK II and Pediatric IOL Calculator. The existence of the Pediatric IOL Calculator provides an alternative to the ophthalmologist for intraocular lens calculation in pediatric patients. Relatively small sample size and unequal distribution of patients especially the younger children (less than 3 years) with a short time follow-up (3 months), considering spherical equivalent only.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of intraocular lens power calculation in pediatric cataracts with less than a 20 mm axial length of the eye.

INTRODUCTION Selection of an appropriately-powered IOL is a complex issue, especially in eyes with an axial length of less than 20 mm in pediatric cataract. OBJECTIVE To assess the accuracy of IOL power calculation formulae in pediatric cataracts in eyes with an axial length of less than 20 mm. MATERIALS AND METHODS The records of children less than 15 years old with congenital cataract who...

متن کامل

Intraocular Lens Power Calculation after Refractive Surgery: A Comparative Analysis of Accuracy and Predictability

PURPOSE To compare the accuracy of intraocular lens (IOL) power calculation using conventional regression formulae or the American Society of Cataract and Refractive Surgery (ASCRS) IOL power calculator for previous corneal refractive surgery. METHODS We retrospectively reviewed 96 eyes from 68 patients that had undergone cataract surgery after keratorefractive surgeries. We calculated the fo...

متن کامل

A Comparison of the American Society of Cataract and Refractive Surgery post-myopic LASI K/PRK Intraocular Lens (IOL) calculator and the Ocular MD IOL calculator

BACKGROUND To compare the average values of the American Society of Cataract and Refractive Surgery (ASCRS) and Ocular MD intraocular lens (IOL) calculators to assess their accuracy in predicting IOL power in patients with prior laser-in-situ keratomileusis (LASIK) or photorefractive keratectomy. METHODS In this retrospective study, data from 21 eyes with previous LASIK or photorefractive ker...

متن کامل

Refractive Changes after Removal of Anterior IOLs in Temporary Piggyback IOL Implantation for Congenital Cataracts

PURPOSE To assess the refractive change and prediction error after temporary intraocular lens (IOL) removal in temporary polypseudophakic eyes using IOL power calculation formulas and Gills' formula. METHODS Four consecutive patients (7 eyes) who underwent temporary IOL explantation were enrolled. Postoperative refractions calculated using IOL power calculation formulas (SRK-II, SRK-T, Hoffer...

متن کامل

SRK II formula in the calculation of intraocular lens power.

We studied 400 eyes which underwent cataract extraction with posterior chamber intraocular lens (IOL) implantation to compare the predictive accuracy of various IOL power calculation formulae. The new Sanders-Retzlaff-Kraff (SRK) II formula was more accurate than the original SRK and Binkhorst II formulae. Modification of the A constants used in the SRK II formula to make it 'surgeon specific' ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010