A new double-tracer gas single-breath washout to assess early cystic fibrosis lung disease.

نویسندگان

  • Florian Singer
  • Georgette Stern
  • Cindy Thamrin
  • Chiara Abbas
  • Carmen Casaulta
  • Urs Frey
  • Philipp Latzin
چکیده

In cystic fibrosis (CF), tests for ventilation inhomogeneity are sensitive but not established for clinical routine. We assessed feasibility of a new double-tracer gas single-breath washout (SBW) in school-aged children with CF and control subjects, and compared SBW between groups and with multiple-breath nitrogen washout (MBNW). Three SBW and MBNW were performed in 118 children (66 with CF) using a side-stream ultrasonic flowmeter setup. The double-tracer gas containing 5% sulfur hexafluoride and 26.3% helium was applied during one tidal breath. Outcomes were SBW phase III slope (SIII(DTG)), MBNW-derived lung clearance index (LCI), and indices of acinar (S(acin)) and conductive (S(cond)) ventilation inhomogeneity. SBW took significantly less time to perform than MBNW. SBW and MBNW were feasible in 109 (92.4%) and 98 (83.0%) children, respectively. SIII(DTG) differed between children with CF and controls, mean±sd was -456.7±492.8 and -88.4±129.1 mg·mol·L(-1), respectively. Abnormal SIII(DTG) was present in 36 (59%) children with CF. SIII(DTG) was associated with LCI (r= -0.58) and S(acin) (r= -0.58), but not with S(cond). In CF, steeply sloping SIII(DTG) potentially reflects ventilation inhomogeneity near the acinus entrance. This tidal SBW is a promising test to assess ventilation inhomogeneity in an easy and fast way.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual gas techniques for peripheral airway function: diffusing the issues

In the quest to investigate small airway function in a range of lung diseases, multiple-breath washout tests have been applied for their potential to represent the most peripheral air spaces [1, 2]. The aim of reducing the burden on the patient has recently also revived interest in the single-breath washout. A single-breath washout test has now been proposed which involves an inhalation of 5% S...

متن کامل

Double tracer gas single-breath washout: promising for clinics or just a toy for research?

Ventilation inhomogeneity reflects the efficiency of gas transport in both central, convection-dependent and peripheral, diffusion-dependent airways. In recent years, there has been a renaissance of studies using inertgas washout to assess ventilation inhomogeneity. This trend is due to promising results of multiple-breath washout (MBW) tests in different populations with various lung diseases,...

متن کامل

Dual gas techniques for peripheral airway function: diffusing the issues.

In the quest to investigate small airway function in a range of lung diseases, multiple-breath washout tests have been applied for their potential to represent the most peripheral air spaces [1, 2]. The aim of reducing the burden on the patient has recently also revived interest in the single-breath washout. A single-breath washout test has now been proposed which involves an inhalation of 5% S...

متن کامل

Multiple Breath Nitrogen Washout: A Feasible Alternative to Mass Spectrometry

BACKGROUND The lung clearance index (LCI), measured by multiple breath washout (MBW), reflects global ventilation inhomogeneity and is a sensitive marker of early cystic fibrosis (CF) lung disease. Current evidence is based on a customized mass spectrometry system that uses sulfur hexafluoride (SF6) as a tracer gas, which is not widely available. Nitrogen (N2) washout may be better suited for c...

متن کامل

Evaluation of ventilation maldistribution as an early indicator of lung disease in children with cystic fibrosis.

Many children with cystic fibrosis (CF), receiving modern, aggressive CF care, have normal spirometry results. This study aimed to see if homogeneity of ventilation distribution is impaired early in the course of CF lung disease, and if ventilation inhomogeneity is a more frequent finding than abnormal spirometry in children benefiting from modern CF care. The study compared spirometry findings...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 41 2  شماره 

صفحات  -

تاریخ انتشار 2013