Quantitative optical coherence tomography analysis for late in-stent restenotic lesions.
نویسندگان
چکیده
Coronary optical coherence tomography (OCT) has the potential to identify in-stent neoatherosclerosis, which is a possible risk factor for late acute coronary events after drug-eluting stent implantation. The purpose of this study was to investigate differences between mid-term and late in-stent restenosis after stent implantation by quantitative and semiautomated tissue property analysis using OCT. In total, 1063 OCT image frames of 16 lesions in 15 patients were analyzed. This included 346 frames of 6 lesions in late in-stent restenosis, which was defined as restenosis that was not detected at 6 to 12 months but ≥ 12 months after follow-up coronary angiography. Signal attenuation was circumferentially analyzed using a dedicated semiautomated software. Attenuation was assessed along 200 lines delineated radially for analysis of the in-stent restenotic lesions (between the lumen and stent contours). All lines were anchored by the image wire to avoid artifacts resulting from wire location. Stronger signal attenuation at the frame level (2.46 ± 0.78 versus 1.47 ± 0.32, P < 0.001) and higher maximum signal intensity at the lesion level (9.19 ± 0.19 versus 8.84 ± 0.32, P = 0.018) were observed in late in-stent restenotic lesions than in mid-term in-stent restenotic lesions. OCT demonstrated stronger signal attenuation and higher maximum signal intensity in late in-stent restenotic lesions than in mid-term in-stent restenotic lesions, indicating the possibility of neoatherosclerosis.
منابع مشابه
Morphological differences of tissue characteristics between early, late, and very late restenosis lesions after first generation drug-eluting stent implantation: an optical coherence tomography study.
AIMS Restenosis of drug-eluting stents (DESs) might be different from that of bare metal stent restenosis in diverse ways including mechanisms and time course; however, these have not been fully examined. To gain insight into the mechanisms and time course of DES restenosis, we evaluated the characteristics of restenotic lesions of first generation DES using optical coherence tomography (OCT). ...
متن کاملDifference of tissue characteristics between early and very late restenosis lesions after bare-metal stent implantation: an optical coherence tomography study.
BACKGROUND Although in-stent restenosis (ISR) after bare-metal stent (BMS) implantation peaks in the early phase, very late (VL) ISR occasionally is observed beyond a few years after BMS implantation. To date, this mechanism has not been fully clarified. METHODS AND RESULTS We compared the morphological characteristics of VL-ISR (>5 years, without restenosis within the first year) (n=43) to t...
متن کاملClinical Implication of Optical Coherence Tomography-Based Neoatherosclerosis
Recent research has indicated neoatherosclerosis (NA), the de novo development of atherosclerosis within the neointimal region of the stented segment after coronary stent implantation, as a mechanism of late/very late stent thrombosis (VLST) and restenosis. This research is based on histologic and intravascular imaging studies. Optical coherence tomography (OCT) is an imaging tool that is super...
متن کاملAssociation between tissue characteristics evaluated with optical coherence tomography and mid-term results after paclitaxel-coated balloon dilatation for in-stent restenosis lesions: a comparison with plain old balloon angioplasty.
AIMS Morphological assessment of neointimal tissue using optical coherence tomography (OCT) is important for clarifying the pathophysiology of in-stent restenosis (ISR) lesions. The aim of this study was to determine the impact of OCT findings on recurrence of ISR after paclitaxel-coated balloon (PCB) dilatation compared with plain old balloon angioplasty (POBA). METHODS AND RESULTS Between J...
متن کاملThe role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography.
BACKGROUND To evaluate the role of integrated backscatter intravascular ultrasound (IB-IVUS) in assessing the morphology of neointima in bare-metal stent (BMS) and drug-eluting stent (DES) restenosis as compared to the gold-standard, optical coherence tomography (OCT). METHODS A total of 120 cross-sections were evaluated by IB-IVUS and OCT at five cross-sections from 24 patients (24 lesions):...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International heart journal
دوره 56 1 شماره
صفحات -
تاریخ انتشار 2015