Comparison of bioimpedance methods for estimating total body water and intracellular water changes during hemodialysis.
نویسندگان
چکیده
BACKGROUND The accurate assessment of body fluid volume is important in many clinical situations. Hannan et al. proposed a single-frequency bioimpedance equation (HE) to calculate extracellular water (ECW) and total body water (TBW). There are two equations based on the bioimpedance spectroscopy (BIS) method for the evaluation of body fluid volume: Xitron equations (XE) and body composition spectroscopy equations (BCSE). The aim of the study was to compare the accuracy of these three equations in body fluid volume point estimation in maintenance hemodialysis (MHD) patients. METHODS The BIS method was performed in MHD patients before and after a hemodialysis (HD) session. TBW, ECW and intracellular water (ICW) were calculated by XE, BCSE and HE, respectively. Hydration status (HS) was calculated using inputs of XE, BCSE and HE. ICW before dialysis was compared to ICW after dialysis. The change of TBW and HS using different equations was compared to actual ultrafiltration volume (AUV) that was calculated as weight difference of pre- to postdialysis. RESULTS Fifty MHD patients (27 females) were included in the study. Significant changes in ICW were observed using the XE and HE method with ultrafiltration (XE: 15.51 ± 5.07 versus 16.17 ± 5.34 L, P < 0.01; HE: 17.40 ± 5.13 versus 16.55 ± 4.71 L, P < 0.01). However, no significant ICW change was observed using BCSE (17.47 ± 4.35 versus 17.54 ± 4.36 L, P > 0.05). ΔTBW_XE and ΔTBW_HE were significantly different from AUV (XE 1.76 ± 0.89 versus 2.46 ± 0.89 L, P < 0.01; HE 4.16 ± 1.36 versus 2.46 ± 0.89 L, P < 0.01); however, ΔTBW_BCSE was much closer to AUV (2.27 ± 0.90 versus 2.46 ± 0.89 L, P = 0.129). The change of HS using inputs of BCSE was also closer to AUV (2.41 ± 0.86 versus 2.46 ± 0.89 L, P = 1.0). CONCLUSION Our study indicated that BCSE provided a better point estimation of ICW and TBW.
منابع مشابه
Measurement of Fluid Status Using Bioimpedance Methods in Korean Pediatric Patients on Hemodialysis
Adequate fluid management is an important therapeutic goal of dialysis. Recently, bioelectrical impedance methods have been used to determine body fluid status, but pediatric reports are rare. To determine the accuracy of bioelectrical impedance methods in the assessment of body fluid statusof children undergoing hemodialysis (HD), 12 children on HD were studied. A multi-frequency bioimpedance ...
متن کاملSegment-specific resistivity improves body fluid volume estimates from bioimpedance spectroscopy in hemodialysis patients.
Discrepancies in body fluid estimates between segmental bioimpedance spectroscopy (SBIS) and gold-standard methods may be due to the use of a uniform value of tissue resistivity to compute extracellular fluid volume (ECV) and intracellular fluid volume (ICV). Discrepancies may also arise from the exclusion of fluid volumes of hands, feet, neck, and head from measurements due to electrode positi...
متن کاملOptimized Blood Volume Monitoring during Hemodialysis Procedure based on Ultrasonic Speed Measurement
Fast reduction of blood water volume due to ultra-filtration via hemodialysis machine and critical threshold of blood water volume can result in clinical complications such as hypotension. When blood water volume reduces during hemodialysis process, the concentration of blood forming elements will increase. One of the methods for the monitoring of the concentration changes is ultrasonic speed m...
متن کاملA comparison of bioimpedance methods for detection of body cell mass change in HIV infection.
The maintenance of body cell mass (BCM) is critical for survival in human immunodeficiency virus (HIV) infection. Accuracy of bioimpedance for measuring change (Delta) in intracellular water (ICW), which defines BCM, is uncertain. To evaluate bioimpedance-estimated DeltaBCM, the ICW of 21 weight-losing HIV patients was measured before and after anabolic steroid therapy by dilution (total body w...
متن کاملTotal Body Water Changes Using Segmental Bioimpedance in Healthy Population with Similar Anthropometry
Electrical bioimpedance was measured in 7 body segments, and also with the standard right-side method, using 11 electrodes at 6 different frequencies in 8 healthy male subjects with similar anthropometry. Our objective was to determine the capability of segmental bioimpedance measurements to estimate small changes of water on each segment (TWsegi) and total body water (TBW) in comparison with t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 26 10 شماره
صفحات -
تاریخ انتشار 2011