Authors' reply regarding "A general three dimensional parametric geometry of the native aortic valve and root for biomechanical modeling".

نویسندگان

  • Rami Haj-Ali
  • Gil Marom
چکیده

We appreciate the comments of Fabius et al. (2013) regarding our general parametric geometric model of native aortic valves (AVs) (Haj-Ali et al., 2012). In their letter, concerns were raised that the use of our geometric model of tricuspid aortic valves (TAVs) might not be suitable when applied for bicuspid valves (BAVs) since it may predict a stenotic configuration. We are glad that Fabius et al. (2013) note that our geometric model is a “good representation” of non-pathologic TAVs, as was the original aim of our proposed mathematical equations. However, the BAV geometry with the fused cusps (Marom et al., 2013), the main concern of the above letter, was actually calculated from a finite element analysis rather than from our TAV geometric model. In the BAV biomechanical analysis of Marom et al. (2013), two of the “TAV” cusps were fused together by moving them into each other to generate the BAV geometry. Fabius et al. (2013) correctly mentioned that in our recent BAV study there is no redundant cusp tissue. Therefore, the motion of the cusp may have been restricted. This representation of BAV geometry is indeed different from our general parametric geometry of TAVs, but it is similar to other previous numerical models (Conti et al., 2010; Jermihov et al., 2011). That is why our calculated opening areas for BAVs were comparable with these previous BAV studies. In summary, our parametric TAV geometry was validated only against three dimensional transesophageal echocardiogram of non-pathologic TAV. We agree with Fabius et al. (2013) suggestion for the need to model BAV specific representation and capture its non-stenotic behavior. Our TAV geometric representation can be extended to include the redundant cusps0 tissue in BAVs and thus generate biomechanical models that can be validated against scans of non-stenotic BAVs. Conflict of interest statement

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A general three-dimensional parametric geometry of the native aortic valve and root for biomechanical modeling.

The complex three-dimensional (3D) geometry of the native tricuspid aortic valve (AV) is represented by select parametric curves allowing for a general construction and representation of the 3D-AV structure including the cusps, commissures and sinuses. The proposed general mathematical description is performed by using three independent parametric curves, two for the cusp and one for the sinuse...

متن کامل

Letter to the Editor regarding "A general three-dimensional parametric geometry of the native aortic valve and root for biomechanical modeling".

With great interest we read the article of Haj-Ali and Marom et al., presenting an extensive three-dimensional mathematical model of the aortic valve and root (Haj-Ali et al., 2012). The development of an accurate model of the aortic valve could provide insight in both the functioning of a healthy valve and several pathological processes involving the aortic valve. As the aortic valve interacts...

متن کامل

Bicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva

Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...

متن کامل

Successful Repair of Type a Aortic Dissection in a Term Pregnancy: A Case Report

Stanford type A acute aortic dissection (AAD) is a very rare complication, with potentially lethal consequences in pregnancy. In fact, pregnancy has been regularly associated with the possibility of aortic. dissection in almost half of young women. Herein, we present the case of a 38-year-old woman in her 37th week of pregnancy. The patient’s medical history was indicative of G4L2Ab1(4 gestaiti...

متن کامل

تعویض دریچه آئورت: مقایسه روش متداول و روش جدید

Background: The usage of pericardium of patient himself, for support of anastomosis lines may carry benefits in patients undergoing aortic valve replacement with pulmonary autograft (Ross). The aim of the present study was to compare the short term results of aortic valve replacement with pulmonary autograft with routine and offered methods. Methods: In a non-randomized clinical trial, 64 pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 47 5  شماره 

صفحات  -

تاریخ انتشار 2014