Ratcheting of 316L stainless steel thin wire under tension-torsion loading

نویسندگان

  • Sichao Fu
  • Dunji Yu
  • Gang Chen
  • Xu Chen
چکیده

A series of cyclic tension-torsion tests under symmetric shear strain and asymmetric axial stress control in various loading paths are conducted on 100 μm-diameter 316L steel wires applying a micro tensiontorsion fatigue testing apparatus. The ratcheting strain of the thin wire increases with increasing axial mean stress and decreases in a sequence of linear, rhombic and circular paths. The macro-scale based cyclic plastic constitutive models with kinematic hardening rules of the Ohno-Wang (OW) and the Chen-Jiao-Kim (C-J-K) are evaluated for the thin wire. Comparing with the O-W, the C-J-K predicts more accurately under high axial stress. While the loading path effects on ratcheting for wire specimens are basically simulated, the macro-based models tend to under-estimate the effect of phase difference between axial and torsional loadings and the ratcheting evolution in the initial 50 cycles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and investigation of TiO2 –SiO2 thin films on AISI 316L stainless steel for tribological properties and corrosion protection

The TiO2–SiO2 thin films were deposited on AISI 316L stainless steel via sol-gel method. Then, the effect of the added amount of SiO2 on the structure, morphology and mechanical properties of the films and corrosion behavior of AISI 316L stainless steel substrate were investigated. So, X-ray diffraction, field-emission scanning electron microscopy, atomic force microscopy, depth-sensing indenta...

متن کامل

Medial malleolar fractures: a biomechanical study of fixation techniques.

Fracture fixation of the medial malleolus in rotationally unstable ankle fractures typically results in healing with current fixation methods. However, when failure occurs, pullout of the screws from tension, compression, and rotational forces is predictable. We sought to biomechanically test a relatively new technique of bicortical screw fixation for medial malleoli fractures. Also, the AO gro...

متن کامل

Fatigue behavior of Austenitic Type 316L Stainless Steel

The aim of this work is to determine the fatigue life of 316L stainless steel. The mechanisms of fatigue of 316L stainless steels were investigated and discussed. The fatigue tests were carried out at constant-amplitude cyclic loading with load ratio R=0.1. Scanning Electron Microscope (SEM) is then used to examine the fracture surface. The results show that the fatigue limit of 316L stainless ...

متن کامل

Shear and tensile plastic behavior of austenitic steel TRIP-120 compared with martensitic steel HSLA-100

Themechanical performanceofTRIP-120, a novel transformation induced plasticity steel alloy, is evaluated for different loading cases and strain rates. The performance is compared with HSLA-100, a lowalloy steel developed by the United States Navy and currently used in naval hulls. The response of these materials under uniaxial tension and shear was investigated to the point of fracture at isoth...

متن کامل

Corrosion and Tissue Reaction to MP35N, L605 & 316L Guide Wires in Combination with a Conventional 316L Cannulated Stainless Steel Screw

INTRODUCTION: Cannulated screws, along with guide wires, are commonly used for a variety of orthopedic indications. Typically they are used for fractures in cancellous regions. Breakage or bending deformation of the guide wire is a clinical concern. Therefore it would be advantageous to use Co-Cr alloys such as MP35N and L605 in these applications as the occurrence of breakages and bendings wou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016