We present the first optimization of linear polyacrylamide (LPA)-based DNA separation matrixes for an automated tandem microchannel single-strand conformation polymorphism (SSCP)/heteroduplex analysis (HA) method, implemented in capillary arrays dynamically coated with poly(N-hydroxyethylacrylamide) (polyDuramide). An optimized protocol for sample preparation allowed both SSCP and HA species to be produced in one step in a single tube and distinguished in a single electrophoretic analysis. A simple, two-color fluorescent sample labeling and detection strategy enabled unambiguous identification of all DNA species in the electropherogram, both single- and double-stranded. Using these protocols and a panel of 11 p53 mutant DNA samples in comparison with wild-type, we employed high-throughput capillary array electrophoresis (CAE) to carry out a systematic and simultaneous optimization of LPA weight-average molar mass (Mw) and concentration for SSCP/HA peak separation. The combination of the optimized LPA matrix (6% LPA, Mw 600 kDa) and a hydrophilic, adsorbed polyDuramide wall coating was found to be essential for resolution of CAE-SSCP/HA peaks and yielded sensitive mutation detection in all 11 p53 samples initially studied. A larger set of 32 mutant DNA specimens was then analyzed using these optimized tandem CAE-SSCP/HA protocols and materials and yielded 100% sensitivity of mutation detection, whereas each individual method yielded lower sensitivity on its own (93% for SSCP and 75% for HA). This simple, highly sensitive tandem SSCP/HA mutation detection method should be easily translatable to electrophoretic analyses on microfluidic devices, due to the ease of the capillary coating protocol and the low viscosity of the matrix.
منابع مشابه
Mutation Detection by Single Strand Conformation Polymorphism and Heteroduplex Analysis
Single strand conformation polymorphism (SSCP) and heteroduplex analysis (HDA) are two of the most popular electrophoresis-based mutation detection methods. Coupled to DNA amplification of the sequence to be analyzed, these techniques have become the methods of choice for a number of molecular diagnostic laboratories. This can be explained mainly by the numerous advantages, namely their technic...
متن کاملFluorescent-based single-strand conformation polymorphism/heteroduplex capillary electrophoretic mutation analysis of the P53 gene.
Fluorescent-based single-strand conformation polymorphism (F-SSCP) analysis with capillary electrophoresis (CE) is the most common method for the detection of mutation because of its high sensitivity and resolution. In this study, we prepared an inexpensive linear polyacrylamide (LPA), and successfully applied it to CE-SSCP analysis and tandem CE-SSCP/heteroduplex analysis (HA) of the P53 gene ...
متن کاملHigh-throughput mutation detection method to scan BRCA1 and BRCA2 based on heteroduplex analysis by capillary array electrophoresis.
BACKGROUND Scanning for mutations in BRCA1 and BRCA2 in a large number of samples is hampered by the large sizes of these genes and the scattering of mutations throughout their coding sequences. Automated capillary electrophoresis has been shown to be a powerful system to detect mutations by either single-strand conformation polymorphism or heteroduplex analysis (HA). METHODS We investigated ...
متن کاملOptimizing DpnI digestion conditions to detect replicated DNA.
Here we describe DNA sample preparation methods that allow the rapid, simultaneous generation of both single-stranded conformational polymorphism (SSCP) and heteroduplex DNA elements from a single sample in a single tube, which are suitable for direct injection into a capillary electrophoresis (CE) instrument with excellent sensitivity of genetic mutation detection. The p53 gene was used as a m...
متن کاملTechnical challenges in applying capillary electrophoresis-single strand conformation polymorphism for routine genetic analysis.
Recent and future advances in population genetics will have a significant impact on health care practices and the economics of health care provision only if a spectrum of patient-tailored, effective methods of DNA screening for sequence alterations has been developed. Genetic screening by capillary electrophoresis-single strand conformation polymorphism (CE-SSCP), which is based upon the differ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 74 11 شماره
صفحات -
تاریخ انتشار 2002