Effect of laser insult on devices used to prevent stone retropulsion during ureteroscopic lithotripsy.

نویسندگان

  • Kaveh Vejdani
  • Brian H Eisner
  • Witsanu Pengune
  • Marshall L Stoller
چکیده

PURPOSE To examine laser damage to three commercially available devices used to prevent stone retropulsion during ureteroscopic lithotripsy. MATERIALS AND METHODS Two experiments were performed with five Accordion, Stone Cone, and NTrap devices each. All devices had a 7-mm outer diameter. The holmium:yttrium-aluminum-garnet laser was set at 8 watts. Experiment 1 was performed in an acrylic tube of 10-mm inner diameter in a saline water bath. The laser was fired against the antiretropulsion element of each device until the device could not be opened or closed. Experiment 2 was performed in a saline water bath; the laser was fired against the carrying catheter of each device until it was severed. RESULTS For experiment 1, the mean number of laser firings against the antiretropulsion element until device failure was 2 for the NTrap, and 28.6 for the Stone Cone. The Accordion was operable after 100 laser firings. The Accordion was more laser resistant than either device (P<0.001, P<0.001), and the Stone Cone was more laser resistant than the NTrap (P<0.001). In experiment 2, mean time to break the carrying catheter was 13.6 seconds for the NTrap, 17.4 seconds for the Stone Cone, and 6.6 seconds for the Accordion. The Stone Cone and NTrap carrying catheters were more laser resistant than the Accordion (P=0.007, P=0.03 respectively), and there was no statistical difference between the Stone Cone and NTrap. CONCLUSIONS The antiretropulsion element of the Accordion was most laser resistant, and both the Accordion and Stone Cone antiretropulsion elements were more laser resistant than the NTrap. The carrying catheters of the Stone Cone and NTrap had similar laser resistance, and both were more laser resistant than the Accordion. Urologists should be mindful of structural characteristics when using these devices.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cost-effectiveness of anti-retropulsion devices for ureteroscopic lithotripsy.

PURPOSE We evaluated the cost-effectiveness of anti-retropulsion devices used during ureteroscopic lithotripsy. MATERIALS AND METHODS A decision analysis model was constructed to compare the cost-effectiveness of ureteroscopic lithotripsy with vs without an anti-retropulsion device. The risk of stone retropulsion was determined from published data in the English language literature. Expected ...

متن کامل

Safety and efficacy of using the stone cone and an entrapment and extraction device in ureteroscopic lithotripsy for ureteric stones

OBJECTIVE To assess the safety and efficacy of using a stone cone and an entrapment and extraction device (N-Trap®, Cook Urological, Bloomington, IN, USA) to avoid stone retropulsion during ureteroscopic lithotripsy for ureteric stones. PATIENTS AND METHODS This retrospective comparative study included 436 patients treated with ureteroscopic lithotripsy for a single ureteric stone from Februa...

متن کامل

[Use of a polymeric gel to prevent retropulsion during intracorporeal lithotripsy].

INTRODUCTION Stone retropulsion during ureteroscopic lithotripsy may lead to additional procedures needed for residual calculi. Several devices have been introduced in an attempt to reduce retropulsion. We set out to report our initial experience utilizing the new polymeric gel, BackStop. MATERIAL AND METHODS We prospectively collected data on 7 ureteroscopy procedures with distal ureteral ca...

متن کامل

Holmium Laser Lithotripsy in the New Stone Age: Dust or Bust?

Modern day holmium laser systems for ureteroscopy (URS) provide users with a range of settings, namely pulse energy (PE), pulse frequency (Fr), and pulse width (PW). These variables allow the surgeon to choose different combinations that have specific effects on stone fragmentation during URS lithotripsy. Contact laser lithotripsy can be performed using fragmentation or dusting settings. Fragme...

متن کامل

The “Guidewire-Coil”-Technique to prevent retrograde stone migration of ureteric calculi during intracorporeal lithothripsy

BACKGROUND Stone retropulsion represents a challenge for intracorporeal lithotripsy of ureteral calculi. The consequences are an increased duration and cost of surgery as well as decreased stone-free rates. The use of additional tools to prevent proximal stone migration entails further costs and risks for ureteral injuries. We present the simple technique of using a coil of the routinely used g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of endourology

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 2009