a-Amylase Determinationwith the Reflotron#{174} Reagent Carrier System: Use of Whole Blood, Plasma, and Serum, and Effectof lsoenzymes
نویسنده
چکیده
11. Un YL, Smith CH, Dietzler DN. Stabilization of blood glucose by cooling with ice: an effective procedure for preservation of samplesfrom adults, newborns. Chin Chem 1976;22:2031-3. 12. Nakashima K, Takel H, Nasu Y, et a!. D-Mannose as a preservative of glucose in blood samples. Chin Chem 1987;33:70810. 13. Kantor N, Wilkerson HLC. The preservation of blood sugar for diabetes detection. Diabetes 1957;6:176-9. 14. Sazama K, Robertson A, Chesler RA. Is antiglycolysis required
منابع مشابه
Use of the Reflotron system for cholesterol assay in capillary blood, venous blood, and serum--evaluation of accuracy and lot-to-lot reagent comparability.
Since its recalibration in 1987, the Reflotron "dry-chemistry" cholesterol method can produce accurate results. Here we report how cholesterol concentrations in venous blood, plasma, and serum determined with Reflotron compare with values determined for fingerstick samples. When no EDTA is used in the latter, accurate results may meet the WHO/CDC criterion of a maximum bias less than or equal t...
متن کاملEvaluationof Determinationof Uric Acid in Serum and Whole Bloodwith the Reflotron#{174}
The performance of the Reflotron system (Boehringer Mannheim) for the determination of urate in whole blood and serum was evaluated. Within-run and day-to-day imprecision of the system were comparable with those for a solutionchemistry enzymatic method (overall CVs in the range 2.22.5%). Results for 100 individual specimens with urate concentrations ranging from 16 to 134 mg/L agreed well with ...
متن کاملBias and precision of cholesterol analysis by physician's office analyzers.
We studied the bias and precision of serum cholesterol analysis by physician's office analyzers. Total imprecision (CV range, %) for analysis of serum pools was: Abbott Vision 1.5%-1.9%; Ames Seralyzer 3.9%-4.5%; BMD Reflotron 2.3%-3.8%; Chrometrics Cholesterol Test System 2.3%-2.8%; Kodak DT-60 1.6%-2.2%. The Ames Seralyzer exhibited an excessive between-run component of variation. We collecte...
متن کاملCOMPREHENSIVE STUDY OF SOME PLASMA BIOCHEMICAL PARAMETERS IN RELATIONTO BONE DISEASE IN HEMODIALYSIS PATIENTS IN ISFAHAN
The concentrations of serum calcitonin', parathormone (PTH), amylase, alkaline phosphatase (ALKP), calcium and phosphorus were studied in pre-and post-dialysis patients with chronic renal failure. All patients had extremely elevated serum urea and creatinine concentrations with the mean values of143.8 and 10.5 mg/dL respectively. The plasma amylase activity was higher than normal with a me...
متن کاملDevelopment of an Agarose Gel Electrophoresis Technique for Determining a-Amylase lsoenzymes
Evaluation of a-amylase isoenzymes as a clinical diagnostic aid by previous methodologies has been either too insensitive or too cumbersome for routine clinical laboratory use. With use of an agarose gel electrophoresis system (Worthington Diagnostic Systems, Inc.) serum amylase activity can easily be resolved into at least nine isoenzymes, the resolution being comparable with that of isoelectr...
متن کامل