Evaluation of Fingerstick Cryptococcal Antigen Lateral Flow Assay in HIV-Infected Persons: A Diagnostic Accuracy Study
نویسندگان
چکیده
BACKGROUND Cryptococcus neoformans is the most common cause of adult meningitis in sub-Saharan Africa. The cryptococcal antigen (CRAG) lateral flow assay (LFA) has simplified diagnosis as a point-of-care test approved for serum or cerebrospinal fluid (CSF). We evaluated the accuracy of the CRAG LFA using fingerstick whole blood compared with serum/plasma and CSF for diagnosing meningitis. METHODS From August 2013 to August 2014, CRAG LFA (IMMY, Norman, Oklahoma) tests were performed on fingerstick whole blood, plasma/serum, and CSF in 207 HIV-infected adults with suspected meningitis in Kampala, Uganda. Venous blood was also collected and centrifuged to obtain serum and/or plasma. CSF was tested after lumbar puncture. RESULTS Of 207 participants, 149 (72%) had fingerstick CRAG-positive results. There was 100% agreement between fingerstick whole blood and serum/plasma. Of the 149 fingerstick CRAG-positive participants, 138 (93%) had evidence of cryptococcal meningitis with a positive CSF CRAG. Eleven participants (5%) had isolated cryptococcal antigenemia with a negative CSF CRAG and culture, of whom 8 had CSF abnormalities (n = 3 lymphocytic pleocytosis, n = 5 elevated protein, n = 4 increased opening pressure). No persons with cryptococcal meningitis had negative fingersticks. CONCLUSIONS The 100% agreement between whole blood, serum, and plasma CRAG LFA results demonstrates that fingerstick CRAG is a reliable bedside diagnostic test. Using point-of-care CRAG testing simplifies screening large numbers of patients and enables physicians to prioritize on whom to measure CSF opening pressure using manometers.
منابع مشابه
1791Evaluating Cryptococcal Antigen Lateral Flow Assay by Fingerstick Whole Blood in HIV-Infected Persons with Meningitis
1791. Evaluating Cryptococcal Antigen Lateral Flow Assay by Fingerstick Whole Blood in HIV-Infected Persons with Meningitis Darlisha Williams, MPH; Kiiza Tadeo,; Sruti Velamakkani,; Reuben Kiggundu,; David Meya, MMed; Joshua Rhein, MD; David Boulware, MD, MPH; Center for Infectious Diseases & Microbiology Translational Research, University of Minnesota, Minneapolis, MN; Infectious Disease Insti...
متن کاملPerformance of Cryptococcal Antigen Lateral Flow Assay Using Saliva in Ugandans with CD4 <100
BACKGROUND Cryptococcal meningitis can best be diagnosed by cerebrospinal fluid India ink microscopy, cryptococcal antigen detection, or culture. These require invasive lumbar punctures. The utility of cryptococcal antigen detection in saliva is unknown. We evaluated the diagnostic performance of the point-of-care cryptococcal antigen lateral flow assay (CrAg LFA) in saliva. METHODS We screen...
متن کاملPerformance of cryptococcal antigen lateral flow assay in serum, cerebrospinal fluid, whole blood, and urine in HIV-infected patients with culture-proven cryptococcal meningitis admitted at a Brazilian referral center
Cryptococcal meningitis is the most common cause of opportunistic meningitis in HIV-infected patients in Brazil and causes unacceptable high mortality rates. In this study, HIV-infected patients with a first episode of culture-proven cryptococcal meningitis in cerebrospinal fluid (CSF) were prospectively included in order to evaluate sensitivity of cryptococcal antigen (CrAg) lateral flow assay...
متن کاملMultisite Validation of Cryptococcal Antigen Lateral Flow Assay and Quantification by Laser Thermal Contrast
Cryptococcal meningitis is common in sub-Saharan Africa. Given the need for data for a rapid, point-of-care cryptococcal antigen (CRAG) lateral flow immunochromatographic assay (LFA), we assessed diagnostic performance of cerebrospinal fluid (CSF) culture, CRAG latex agglutination, India ink microscopy, and CRAG LFA for 832 HIV-infected persons with suspected meningitis during 2006-2009 (n = 29...
متن کاملLateral Flow Assay for Cryptococcal Antigen: an Important Advance to Improve the Continuum of Hiv Care and Reduce Cryptococcal Meningitis-related Mortality
AIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg) in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex) or enzyme-linked immunoassay (EIA) has been available for over decades. Better diagnostics in asymptomatic and sy...
متن کامل