Operation of a CCD particle detector in the presence of bulk neutron damage

نویسندگان

  • James E. Brau
  • Nikolai Sinev
چکیده

The use of CCDs in future linear collider experiments will require immunity to large neutron fluences, in excess of /year. The effects on charge transfer efficiency of neutron induced bulk damage are presented along with a demonstration of a technique to fill the traps with sacrificial charge. Operation is then possible at fluences in excess of .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and calibration of a passive detector for separating neutron, proton and alpha particles in mixed radiation fields

In this study, calibration process was carried out for deigned new CR-39 nuclear track detector for protons, neutrons and alpha particles separately under the same etching condition. In order to aim this purpose, americium-beryllium standard source (241Am-Be) and Plexiglas phantom for neutron irradiation, brass collimators and americium standard source (241Am) for alpha irradiation and the acce...

متن کامل

بهینه‌سازی پاسخ دزیمتری نوترون در بازه انرژی حرارتی و سریع برای آشکارساز دیودی

During the last few years, real time gamma and neutron dosimeters have been developed and semiconductor diodes are frequently used in these dosimeters. Semiconductor diodes are used to charged particle detection. For sensitizing the detector to neutrons, a converter layer is contacted on the front surfaces of them. Incident neutrons interact with the converter and produce charged particles that...

متن کامل

Investigation of the operation of Thick Gas Electron Multiplier and Electron Multiplier Assembly for alpha particle detection

In this study, the detection of alpha particles in the high current mode is investigated in the presence of two gaseous electron multipliers in the micro-pattern structures. Thick Gas Electron Multiplier (TGEM) and an Electron Multiplier Assemblies (EMA) were designed and constructed as amplification gap in the detector chamber. An ion chamber is employed to measure the current of interaction b...

متن کامل

The effect of source shield on landmine detection

Background: Several landmine detection methods, based on nuclear techniques, have been suggested during the recent years. Neutron energy moderation, neutron-induced gamma emission, neutron and gamma attenuation, and fast neutron backscattering are nuclear-based methods used for landmine detection. The aim of this study is to use backscattered neutron for landmine detection. Materials ...

متن کامل

Electron and Neutron Radiation Damage E ects on a Two - Phase CCD

Ionization and bulk radiation damage e ects in a two-phase CCD, operated in a Multi Pinned Phase (MPP) mode have been evaluated. Two-phase CCD's are one of the candidates for application in the vertex detector of a future linear collider. Flat-band voltage shifts, dark current, dark current spikes and charge transfer e ciency (CTE) were studied on devices, subjected to irradiation with uencies ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999