Comparison of independent optical frequency measurements using a portable iodine-stabilized nd:yag laser - Instrumentation and Measurement, IEEE Transactions on

نویسندگان

  • Feng-Lei Hong
  • Jun Ishikawa
  • Kazuhiko Sugiyama
  • Atsushi Onae
  • Hirokazu Matsumoto
  • Jun Ye
  • John L. Hall
چکیده

A comparison of two independent absolute optical frequency measurements has been carried out between the National Metrology Institute of Japan/National Institute of Advanced Industrial Science and Technology (NMIJ/AIST), Tsukuba, Japan and the JILA (formerly the Joint Institute for Laboratory Astrophysics), Boulder, CO, using a portable iodine-stabilized Nd:YAG laser. The agreement between the two absolute measurements is better than the measurement uncertainty of 6.7 10 13 that can be attributed to the reproducibility limitations of the portable laser. This comparison is used to confirm the measured absolute frequency of an iodine-stabilized Nd:YAG laser at NMIJ/AIST (Y3), which is reported to the Consultative Committee for Length (CCL) for the determination of the absolute frequency value of iodine-stabilized Nd:YAG lasers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Portable I2-stabilized Nd: YAG laser for international comparisons

We have established a compact and transportable I2-stabilized Nd:YAG laser for international comparisons of laser frequency. The root Allan variance of the portable laser has reached 3 9 10 14 when the integration time is longer than 200 s. The results of an international comparison between the National Research Laboratory of Metrology (NRLM), Tsukuba, Japan and the JILA (formerly the Joint Ins...

متن کامل

Measurement of Iodine Cell Purity and Absolute Frequency Shifts for Laser Stabilization

− This contribution deals with the investigation of uncertainties achievable through stabilization of lasers using saturated absorption in iodine vapour. The main focus is on the iodine cell technology and evaluation. We present results from two independent methods for the measurement of the purity of molecular iodine in absorption cells. The purity was tested by improved method based on measur...

متن کامل

Stabilization and frequency measurement of the I2-stabilized Nd: YAG laser

We report improved stabilization results for and progress toward a more accurate frequency measurement of the 532 nm iodine-stabilized system based on a frequency-doubled Nd : YAG ring laser. We confirm the CCL-adopted frequency well within its stated uncertainty ( 40 kHz).

متن کامل

Ultrahigh long-term dimensional stability of a sapphire cryogenic optical resonator.

We report on the ultrahigh long-term dimensional stability of a crystalline cryogenic optical resonator (CORE) cooled to liquid-helium temperature. The frequency of a Nd:YAG laser stabilized to a CORE was compared over long times with an independent laser system, a frequency-doubled Nd:YAG laser stabilized to a hyperfine line of molecular iodine at 532 nm. Over a 6-month period the drift was le...

متن کامل

Absolute frequency stabilization of diode-laser-pumped Nd:YAG lasers to hyperfine transitions in molecular iodine.

Diode-laser-pumped Nd:YAG lasers were frequency stabilized by locking their frequency-doubled output to Doppler-free absorption lines of the (127)I(2) molecule. The successive two-sample deviation of the beat frequency between two independent iodine-stabilized lasers is less than 650 Hz, or 2.3 x 10(-12) of the laser frequency, for averaging times between 24 and 80 s.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001