Effects of physiologic human brain motion on proton spectroscopy: quantitative analysis and correction with cardiac gating.

نویسندگان

  • Pradip M Pattany
  • Imad H Khamis
  • Brian C Bowen
  • Karl Goodkin
  • R Gregory Weaver
  • James B Murdoch
  • M Judith Donovon Post
  • Robert M Quencer
چکیده

SUMMARY Proton MR spectroscopy is a powerful noninvasive method that enables measurement of certain brain metabolites in healthy subjects and patients with diseases. A major difficulty with clinical and research applications of in vivo proton MR spectroscopy is the variability of metabolite concentrations, especially in regions with substantial physiologic motion. In our preliminary evaluation, we tested the hypothesis that physiologic brain motion leads to lower mean metabolite concentrations and higher SDs for the measured metabolite concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative analysis of the effects of physiologic brain motion on point-resolved spectroscopy.

BACKGROUND AND PURPOSE Although single-voxel proton MR spectroscopy is a noninvasive method that enables measurement of brain metabolite concentrations, it has been shown that physiologic brain motion causes inaccuracies in measurement of metabolite concentrations and increases the overall SD of the measurements when the stimulated echo acquisition mode (STEAM) is used. We tested the hypothesis...

متن کامل

Advanced Motion Correction Methods in PET

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...

متن کامل

Investigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study

Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...

متن کامل

Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer

AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...

متن کامل

A Simplified Pipeline for Motion Correction in Dual Gated Cardiac PET

Positron Emission Tomography (PET) is a nuclear imaging technique of increasing importance e.g. in cardiovascular investigations. However, cardiac and respiratory motion of the patient degrade the image quality due to acquisition times in the order of minutes. Reconstructions without motion compensation are prone to spatial blurring and affected attenuation correction. These effects can be redu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 23 2  شماره 

صفحات  -

تاریخ انتشار 2002