Relationship Between Tei Index and PEP-Derived Myocardial Performance Index in Sinus Rhythm

نویسندگان

  • Feyzullah Besli
  • Cengiz Basar
  • Ismail Ekinozu
  • Yasin Turker
  • Leischik. Roman
چکیده

The goal of this study was to evaluate the preejection time (PEP)-derived myocardial performance index (MPI) in hypertensive (HT) patients with sinus rhythm and its relationship to the classic Tei index. One hundred five patients were enrolled in the study (65 HT and 40 control subjects). The mean age of all patients was 50.5 ± 15 years and 60% were female. Echocardiography was performed on all patients. MPI was measured with the classic Tei method (MPI-Tei index) and the PEP-derived MPI method by using tissue Doppler echocardiography. Although the MPI-Tei index is defined as the ratio of isovolumetric contraction time (IVCT) along with isovolumetric relaxation time (IVRT) to ejection time (ET), PEP-derived MPI is defined as the ratio of PEP and IVRT to ET. We compared echocardiographic data between the HT group and the control group. MPI-Tei index and the PEP-derived MPI values were higher in the HT group compared with controls (0.52 ± 0.10 vs 0.39 ± 0.07, P < 0.001, and 0.51 ± 0.09 vs 0.39 ± 0.07). PEP-derived MPI was strongly correlated with the MPI-Tei index (r = 0.945, P < 0.001). Our study determined that the PEP-derived MPI might be used in the evaluation of left ventricular function in patients with HT, similar to the classic MPI-Tei index.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler-Derived Myocardial Performance Index in Healthy Children in Shiraz

Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...

متن کامل

Tei Index Obtained from Tissue Doppler Imaging: Correlation with Ntprobnp Levels in Patients with Dilated Cardiomiopathy

The myocardial performance index (Tei index) determined by the pulsed Doppler is a simple and noninvasive measurement for assessing global left ventricular (LV) function. This index can also be obtained by tissue Doppler imaging (Tei-TDI). The purpose of our study was to assess the relationship between Tei-TDI and N-terminal pro-brain natriuretic peptide (NTproBNP) levels in patients with dilat...

متن کامل

[Influence of preload reduction on Tei index and other Doppler echocardiographic parameters of left ventricular function].

OBJECTIVE To assess the influence of preload reduction by hemodialysis on Doppler Tei Index of myocardial performance and other parameters of cardiac function. METHODS The Tei index and left ventricular (LV) systolic and diastolic function parameters were estimated, before and after a single hemodialysis session. Only subjects who were in sinus rhythm, without history of coronary artery disea...

متن کامل

Relationship between Tei index of myocardial performance and left ventricular geometry in Nigerians with systemic hypertension

INTRODUCTION Left ventricular geometry is associated with cardiovascular events and prognosis. The Tei index of myocardial performance is a combined index of systolic and diastolic dysfunction and has been shown to be a predictor of cardiovascular outcome in heart diseases. The relationship between the Tei index and left ventricular geometry has not been well studied. This study examined the as...

متن کامل

The Tei index of myocardial performance: applications in cardiology.

of classical echocardiographic indexes for the estimation of systolic and diastolic left ventricular (LV) function. The ejection fraction (EF, an index of systolic function) and LV volumes are subject to large errors when the ellipsoid shape of the heart becomes spherical. Age, rhythm and conduction disturbances, and changes in loading all affect the Doppler signal of transmitral flow, which is...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 94  شماره 

صفحات  -

تاریخ انتشار 2015