Preliminary clinical experience of a contracture correction device.
نویسندگان
چکیده
Joint contractures which do not respond to conventional physiotherapy can be difficult to treat. Serial plastering has been used effectively but is expensive, inconvenient to the patient and does not permit daily hygiene or clinical inspection. A mechanical device has been developed consisting a hinged orthosis which spans the affected joint to which is attached a gas strut to provide a corrective moment about the anatomical joint. Such an arrangement enables prescribed corrective moments to be applied accurately following clinical assessment using routine physiotherapy techniques. The inherently low spring rate of a gas strut ensures that the specified corrective torque is maintained as correction occurs. Initial treatment experience under the control of the developers had generated wider interest in the system. A geographically distant independent orthotic supply centre was trained in the techniques of application. They treated nine elbow and three knee joints in patients who had not responded to physiotherapy treatment. All of the patients experienced improvement. The average for elbow joints was a reduction in the contracture of 25.6 degrees with a corrective moment of 6.8 Nm over a period of 3.9 weeks. For the knee joints the averages were a reduction in contracture of 10.7 degrees with a corrective moment of 12.7 Nm over a period of 4 weeks. The results confirmed the practicality of transferring the system to independent clinical centres and provide evidence to support funding for a formal prospective clinical trial of the treatment approach.
منابع مشابه
A technique for correction of equinus contracture using a wire fixator and elastic tension.
Equinus contracture often is a complication of trauma, burns, or neurologic deficit. Many patients with contractures secondary to trauma or burns have poor soft tissue, which makes invasive correction a less appealing option. The Ilizarov external fixator has been used as a less invasive attempt to correct equinus contracture. We describe our "dynamic" technique and present a clinical patient s...
متن کاملModified Colzi method in the management of established Volkmann contracture--the experience of Trzebnica Limb Replantation Center (preliminary report).
BACKGROUND "The terrible disability of irreversible ischaemic flexion contracture of the metacarpi and digits known as Volkmann's contracture can be avoided in the vast majority of cases, but never completely cured" (M. Koszla). A modification of Colzi's forgotten technique for the treatment of Volkmann's contracture is presented together with our treatment outcomes. MATERIAL AND METHOD The C...
متن کاملComparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries
Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...
متن کاملTotal knee arthroplasty in patients with greater than 20 degrees flexion contracture.
Fixed flexion contracture can present a technical challenge in total knee arthroplasty. Various techniques of addressing these deformities have been described including additional bony resection, ligamentous releases, and the use of increasing constraint. We retrospectively reviewed the clinical outcomes of 40 patients (52 knees) with fixed flexion contracture greater than or equal to 20 degree...
متن کاملEvaluation of human allogeneic collagen gel for correction of nasolabial folds using non-invasive measurement techniques
Background: With aging, the facial folds, grooves, and sagging tissue become more prominent. It is haracterized by loss of the collagen mass in the dermis and an increased array of elastin whirls in the deeper dermis. The aim of this study was to determine whether correction of nasolabial folds could be achieved using an allogeneic collagen product. Methods: Nine healthy volunteers participated...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Prosthetics and orthotics international
دوره 23 2 شماره
صفحات -
تاریخ انتشار 1999